G
B
erasing will be indicated by two flashes of the green LED DL9.
The red LED DL1 will blink for 10 seconds and it will be possible to
store new radio codes following the Point E procedure described
above.
5 - To end radio code storing either press PROG button or let 10 seconds
pass. The LED DL1 shall stop blinking.
6 - Turn DIP1 to OFF position.
7 - Turn DIP2 to OFF position.
POINT G
- RADIO CODE FULL MEMORY TEST (ONLY
FOR CRX)
1 - The boom arm must be completely closed.
2 - Turn DIP1 to ON position, the red LED DL1 starts blinking quickly.
3 - Immediately, turn also DIP2 to ON position, the red LED DL1 starts
blinking slowly.
If the green LED DL9 flashes six times, it means that the radio code
F
UNCTIONING OF CONTROL ACCESSORIES in NORMAL MODE (DIP6 OFF)
OPEN1 BUTTON (COM - OPEN1)
The OPEN1 button performs the open
command, regardless the position of the
boom arm. If the OPEN1 button is pressed
during the closing, the boom arm stops and
will reverse the movement in opening.
In PARK MODE (DIP6 ON), if there is
a vehicle at the entry (see scheme 4) and
the TLC contact is closed, the OPEN1
command opens the barrier. Otherwise,
if the TLC contact is open the OPEN1
command is disabled.
CLOCK FUNCTION
The Clock Function permits to keep the
boom arm opened even if, for example, the
Automatic Closing is enabled (DIP3 ON) or
somebody commands the barrier closing.
It is useful during rush hour, when traffic is
heavy and the flow is low (e.g. entrance/exit
of employees, emergencies in residential
areas or car parks) and it's necessary to
keep the boom arm opened.
It can be done by connecting a switch and/
or a daily/weekly timer either in parallel to
the OPEN1 button or instead of the OPEN1
button. When the control board receives
this command, the boom arm will open and
by keeping this contact closed for all the
time of the boom arm opening, the Clock
Function is automatically activated.
In fact, once reached the open position, the barrier will remain opened
and all of the control board features are blocked. Only when the OPEN1
button is released, the control board functions are re-activated and the
boom arm will close immediately.
CLOSE BUTTON (COM - CLOSE)
The CLOSE button performs the close command, regardless the
position of the boom arm.
STEP BY STEP or AUTOMATIC COMMANDS (COM - K BUTT)
DIP5 - OFF => The K BUTT performs the cyclic command open-stop-
close-stop-open etc.
DIP5 - ON => The K BUTT performs:
- the open command, if pressed with the barrier
completely closed
- the close command, if pressed with
completely opened
- no effect, if pressed during the barrier opening
- the boom arm re-open, if pressed while the barrier is
closing
6 - Turn DIP1 to OFF position.
7 - Turn DIP2 to OFF position.
+
K BUTTON
LED
R=2K2
STOP
CLOSE
+
OPEN 1
LSC
LSO
LSSC
LSSO
TIMER
the barrier
30
30
memory is FULL (maximum codes to be stored 60).
AERIAL
+
COAX
BUZZER
-
_
_
12 Vdc max 0,5A for ACCESSORY SUPPLY
+
_
12 Vdc max 0,5A for AUTOTEST EDGE
+
REMOTE CONTROL
DIP4 - OFF => The REMOTE CONTROL performs the cyclic command
open-stop-close-stop-open etc.
DIP4 - ON => The REMOTE CONTROL performs:
- the open command, if pressed with the barrier completely
closed
- the close command, if pressed with the barrier completely
opened
- no effect, if pressed during the barrier opening
- the boom arm re-open, if pressed while the barrier is
closing
AUTOMATIC CLOSING (DIP3 ON)
The Automatic Closing from the complete open position can be enabled
turning ON the DIP3. The maximum time that can be programmed is 5
minutes (see point D).
ENTRY
EDGE
NC
NO
COM
S
S
D-
D-
D
+
D
MAGNETIC LOOP
TO EXIT