User Safety; Set Up For Installation - Jacuzzi J-315 Ficha Técnica De Preinstalación

Tabla de contenido
Weights
net weight
average fill
kg
litres
J-315
~ 227
~ 795
J-335
~ 368
~ 1249
~ 1287
J-345
~ 373
~ 400
~ 1476
J-355
~ 1571
J-375
~ 435
~ 1400
J-LXL
~ 400
area involved
support area
m
2
J-315
~ 3,24
~ 2,56
J-335
~ 4,54
~ 3,72
J-345
~ 4,54
~ 3,72
J-355
~ 4,92
~ 4,07
J-375
~ 5,34
~ 4,45
J-LXL
~ 4,55
~ 4,23

User safety

I
The system, if installed by qualified personnel, does not present
any hazard for the user. Safety is however also contingent upon
proper use, as set forth by the user's manual included with the
product. The user must contact qualified personnel for special
operations described in the manual.
I
It is important to make sure that personnel tasked to install and
manage the system are qualified as per legal requirements in
effect in the country where installation is carried out.
I
Periodically, however, the differential switch (see "ELECTRICAL
SAFETY" chapter) of the system to which the mini-pool is con-
nected must be checked for efficiency. When you press the
TEST key, the switch must disconnect. If this does not
happen, disconnect the power supply immediately and
contact a qualified technician.
I
For any extra maintenance and/or repairs it is recommended that you
contact an Authorized Service Centre and use only original spare parts.

Set up for installation

I
Premium spas are equipped with the drain arranged as in
1-1a-1b-1c, det.A.
The customer must make provisions for a ground drainage point
of suitable dimensions and that can be inspected for any cleaning
that may be required.
ATTENTION: Before preparing the ground drainage
point, consult the local authority for the regulations
that control the drainage of chemically treated water.
I
For periodic emptying of the spa you can connect a rubber hose
i
to the drain valve (
1-1a-1b-1c, det. A).
NOTE: To open the valve, turn the ring nut counter-clockwise and pull.
If you decide to attach the spa to the drain, it is advisable to con-
maximum
max. weight
water volume
litres
~ 1037
~ 1715
~ 1734
~ 1836
~ 2006
~ 1839
average load
load concentrated
on area involved
on support area
m
2
kg/m
2
~ 390
~ 459
~ 464
~ 454
~ 457
~ 446
nect upstream from the valve (for greater flow capacity) and to
install a shutter valve near the drain in an accessible area (
1-1a-1b-1c, detail A1).
total
kg
I
According to the type of installation chosen the ground drainage
~ 1264
point will then be put into position.
~ 2083
installed in a variety of ways:
~ 2107
~ 2236
- Free standing on the floor or on a specifically prepared base
~ 2441
i
(
4).
~ 2234
- Semi-built in, so that only the base of the spa is built-in and
therefore the side cover panels remain free (
kg/m
2
~ 494
it is appropriate to prepare some removable under-frames (in
~ 560
marine plywood, etc.) that, besides aesthetically completing in-
~ 566
stallation, allow the panels to be removed more easily.
~ 549
~ 548
I
In any case you will need to provide a support base that is suit-
~ 528
able for the selected model, taking into consideration the data
contained in the table "Weights".
I
You can use a garden hose to fill the spa.
If the spa is connected, for periodic filling, to the mains
system that supplies drinking water, this connection
must be carried out in compliance with the EN1717 norm,
using "AA", "AB" or "AD" anti-pollution protection proce-
dures. For further information, we recommend you con-
tact your water supply company and/or your plumber.
I
For indoor installation, it is necessary to remember that water
evaporation from the spa (especially where high temperatures are
involved) can cause very high levels of humidity. Natural or forced
ventilation helps to maintain personal comfort and reduce damage
to the building due to humidity.
Jacuzzi Europe refuses all responsibility for any damage caused
by excessive humidity or by overflowing water. Consult a spe-
cialist for indoor installation.
I
Remember that it is compulsory to install a multiple-pole section
switch with characteristics that are not less than the ones given in
the chapter "Electrical safety" and
I
The installer must use cables with an adequate cross-section,
protected by a sheath and/or with tubes or ducts, with character-
i
istics not inferior to type H 05 VV-F.
The entry of cables into the mini-pool up to the electrical box (
2) must be provided at point B or B1, depending on the customer's
installation needs.
Note: The lead sections must take account not only the
systems absorption but also the cable path and the dis-
tances, the chosen protection systems and the specific
regulations for fixed electrical systems in force in the
country where the spa is installed.
I
The installer must comply with the above regulations, and also use
watertight connectors at connection points. He must also
guarantee compliance with the specific current standards for
systems in the country in which the spa is installed.
14
The Premium spas can be
i
5). In this case,
i
2.
i
i
Tabla de contenido
loading

Este manual también es adecuado para:

J-335J-345J-355J-375J-300J-lxl

Tabla de contenido