4.4 Programming of the course
This procedure must be carried out ONLY by an installer and ONLY during the setting up of the system.
For a correct programming, before carrying out any modification, bring always again the gate in totally closed position (see section 4.2).
SW1 Position
MAN
AUT
Press shortly the BLUE key. The
door starts to open slowly.
When the door reaches the desired opening
position, press again the BLUE button. The door
stops itself. The flashing light blinks fast.
Press the 1° button of the transmitter or the step by
step button. The gate closes completely.
When the gate reaches the closing position it stops
automatically. The flashing light blinks slowly.
Press the 1° button of the transmitter or the step by
step button. The door opens completely, once
opened, the flashing light carries out 4 blinking.
4.5 Adjusting of the anti-squashing security
This procedure must ONLY be carried out by the installer and ONLY during the setting up of the system. For a correct programming the door must
be manually moved with an effort lower than Kg.15. Before of carrying out any modification, bring always the gate in totally closed position (see
chapter 2)
SW1 Position
MAN
AUT
Warning: with the trimmer in position DISABLE (flashing light turned on) the anti – squashing security is excluded.
6-1622356 rev.4 09-07-2013
Press shortly the BLUE but-
ton. The flashing light starts
to blink slowly.
SI
SI
SI
SI
SI
SI
The course is memo-
Set the trimmer at
the minimum
A few sensitive
Rotate the TORQUE STOP
trimmer in anticlockwise sense
to lower the motor's torque
Force decrease
ITA
NO
Check that the door is closed and that SW1
position is in AUTO position and repeat the test.
NO
Check the wiring of the motor. Repeat the test.
NO
Press again the BLUE key.
WARNING:
During the memorization of the course and for the successive 2
complete cycles of movement (closing and opening), avoid
interventions on the stop and photocells inputs, avoid also the
testing of the sense, because the control unit gets in these 2
first memorizations the parameters for a correct functioning.
WARNING:
If the gate has stopped itself during the movement, bring it again
on close position manually, putting SW1 in manual and utilizing
the YELLOW button on the card. Once closed bring again SW1
in automatic position and restart from the beginning.
With the automation in movement,
check the sensitivity of the anti –
squashing security intervention
and check that the gate regularly
works.
Too much sensitive or not regu-
larly functioning.
NO
Rotate the TORQUE STOP
trimmer in clockwise sense to
increase the motor's torque
Repeat the
sensitivity
measure
ENG
FRA
ESP
DEU
POR
Check that the functioning is
regular and that the sensitivity is
SI
set in correct way, increase lightly
the trimmer to balance the frictions
which can change with the time
and the temperature.