5. Advanced functions
These procedures are turned ONLY to the installer and ONLY during the setting up of the system.
For a correct programming, before to carrying out any modification bring again the gate in totally closed position (see section 4.2).
N° blink
Selected function
1
Pre-flashing
2
Photocell Test
3
Condomonium setting
4
Inversion on photocells
5
Clock
6
Inversion on sens
Activation configuration menu
To modify the state of any of these functions it is necessary to activate the configuration menu. This particular state of the control unit can be
activated only from stop door and completely closed. In the configuration menu the control unit automatically slides the functions on which it is
possible to intervene. The flashing light' led signals the function selected once and once with a variable number of blinking. The passage from one
function to another one is carried out automatically (it is enough to keep the red button always pressed). The control unit starts selecting the first
function (signaled by 1 blinking), successively keeping pressed the red key you pass to the second function (signaled by 2 blinking) and so on.
To enable the learning modality proceed as follows:
1.
Close the door completely
2.
Press and keep always pressed the red button
3.
After 4-5 seconds the led carries out a series of 8 blinking (which signal the activation of the configuration menu). Once finished the series of
blinking the control unit is entered in the configuration menu. Do not release the button yet
4.
Once individuated (through a number of blinking of the flashing light led) the function which you desire to modify, release the red key. Like
this the desired function is selected. Once selected the function, the control unit points out the setting blinking with a slow frequency (1
blinking/second) or with a rapid frequency (2 blinking/second) to indicate if the function is active or not according on what reported on the
table.
5.
Then press the correspondent button (make reference to the table) at the new state which you desire to set for the selected function. The
blinking frequency will change according to the choice done.
At this point it is possible to modify further functions, or , if you ended, to exit from the learning phase. In case you desire to modify other functions,
press and keep pressed again the red key. After a few seconds the control unit will start again to select in sequence the various functions. Then
proceed as explained above.
If instead you desire to exit from the learning, it is enough to bring the lever of the selector S1 in manual position, wait 1-2 seconds and successively
bring it again in automatic position. Like this, the control unit exits from the learning modality and predisposes itself for the normal functioning.
5.1 Pre-flashing
Activating the function, the pre-flashing is enabled. This function carries out BEFORE of each movement a series of blinking to indicate the imminent
movement.
5.2 Photocells test
This control unit has a function (settable by menu), which allows to carry out a check on the photocell's functioning before of each activation of the
motor. Like this you have the possibility to increase the security of the system in case of damaging of the photo – device (for example output relay
glued), or of un undesired short – circuit in the photocell's input.
In case of failure, the control unit signals it carrying out one single blinking at the pressure of a button and not carrying out any movement.
This checking is carried out after that the control unit has received a control to move, but before to give tension to the motor.
5.3 Condominium function
With this function active, each control given via radio or by step by step buttons and/or pedestrian causes only the opening of the door.
The closure is entrusted to the automatic reclosing function, which will have therefore to be NECESSARILY ACTIVATED, because each control of
closing is ignored. In case in which the condominium function is active and the automatic reclosing is disabled by the respective adjusting trimmer
(rotate all in clock-wise sense), the control unit puts itself in state of alarm signaled by quick blinking of the flashing light.
5.4 Inversion on photocell
With this function active, the control unit does not stop the movement during the opening phase, in case of interruption of the photocell's beam, while
inverts completely if the interruption happens during the closure.
Deactivating this function, the control unit locks the movement, both in opening and in closing until the removing of the obstacle.
Once removed the obstacle, the control unit starts the automation in opening.
5.5 Clock function
Activating the clock function, the PEDESTRIAN function becomes clock input where it is possible to connect a timer for the programmed opening of
the automation. The contact is interpreted like request of opening and permanence on open state until the contact remains closed.
When the contact opens itself, the automation automatically closes itself.
5.6 Inversion on sense
With this function active, if a sense is detected during the opening phase, the control unit blocks and inverts completely unless in the last centimeters
of the course, where it carries out a brief inversion.
Deactivating this function, the control unit locks the movement both in opening and in closing, if a sense is detected until a next control.
6-1622356 rev.4 09-07-2013
Blink
Slow = disabled / Fast = enable
Slow = disabled / Fast = enable
Slow = disabled / Fast = enable
Slow = disabled / Fast = enable
Slow = disabled / Fast = enable
Slow = disabled / Fast = enable
ITA
ENG
FRA
ESP
Yellow button
Blue button
activation
deactivation
activation
deactivation
activation
deactivation
activation
deactivation
activation
deactivation
activation
deactivation
DEU
POR
Factory setting
Not active
Not active
Not active
active
Not active
active
pag. 6 di 8