English
1
User information
The module CPX-CTEL-4-M12-5POL has been designed
exclusively for the control of pneumatic and electric actu
ators, for interrogating sensor signals by means of input
modules and for communication via I-port.
The specified limits for technical data must be adhered to.
Detailed information can be found in the description for
the CPX-CTEL-Master (P.BE-CPX-CTEL-...) and the CPX-sys
tem description (P.BE-CPX-SYS-...).
Warning
Switch off the power supply before assembling or
disassembling modules or plugging plug connectors
together or separating them (danger of operative
malfunctions or damage).
Use only power units which guarantee reliable
electrical isolation of the operating voltage as per
IEC/DIN EN 60204-1. Observe also the general
requirements for PELV circuits.
Connect an earth conductor of sufficient cable cross
section to the connection of the CPX terminal marked
with the earth symbol.
The CTEL master includes electrostatically sensitive
devices. Therefore, do not touch any components.
Observe the handling specifications for
electrostatically sensitive devices.
Note
Only commission a CPX terminal which has been
mounted and wired completely.
Festo CPX-CTEL-Z6 1411a English
15