Service Level; Modifying The Switch Assignment - Grundfos DMX 221 Manual Del Usuario

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 73

8.8 Service level

Open the service level to modify the switch assignments of the
electronics.

8.8.1 Modifying the switch assignment

You are modifying the default settings of your
Note
AR control unit. They will therefore differ from the
technical data.
The service level can only be accessed when the power supply is
being switched on.
1. Simultaneously press the "Menu/Info" and "Down" buttons,
and hold them down.
2. Switch on the power supply.
– The LED lights up green for approximately 3 seconds and
turns yellow.
3. Release the "Menu/Info" and "Down" buttons.
4. Press the "Start/Stop" button.
5. Press the "Up" button.
– "Func" appears in the display.
6. Press the "Menu/Info" button.
– The service level is opened.
Pump not connected to power supply
Keep pressed when switching on
LED first lights up green, then yellow
Fig. 31 Service level
1. Navigate in the service level by repeatedly pressing the
"Menu/Info" button.
2. Use the "Up" and "Down" buttons to modify the switch
assignment in the relevant menu.
3. Press the "Start/Stop" button
– to confirm the new settings
– to exit the service level
– to open the first function level.
If no button is pressed for approximately 30 seconds,
the service level is exited and the first function level
Note
is opened.
24
Down
+
Menu
Stop
Start
Up
Menu
1: relay function (stroke/pre-empty signal selection)
2: remote off, NO/NC input
3: pre-empty signal, NO/NC input
4: empty signal, NO/NC input
5: error signal, NO/NC output
6: relay output, NO/NC (stroke signal/pre-empty signal)
7: hall sensor on/off
8: locking "run" on/off
Switch the power supply off and on again
to save the settings
Stop
Start
(or 30 seconds without button pressed)
Service level
Tabla de contenido
loading

Este manual también es adecuado para:

Dmx 226Dmh 25xDmh 28x

Tabla de contenido