Safety Instructions; Safety Symbols - RS Pro RS-660 Manual De Instrucciones

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

1-Safety Instructions

This meter has been designed for safe use, but must be operated with caution. The rules
listed below must be carefully followed for safe operation.
• NEVER apply voltage or current to the meter that exceeds the specified maximum:
Input Limits
Function
Maximum Input
VAC
600 V dc/ac
V DC or V AC
600 V dc/ac, 200 V rms on 200 mV range 200 mA
mA DC
600 V fast acting fuse
10 A 600 V fast acting fuse (30 seconds max every 15 minutes)
A DC
250 V rms for
Resistance, Continuity 15 seconds max
• USE EXTREME CAUTION when working with high voltages.
• DO NOT measure voltage if the voltage on the "COM" input jack exceeds 500 V above
earth ground.
• NEVER connect the meter leads across a voltage source while the function switch is in
the current, resistance, or diode mode. Doing so can damage the meter.
• ALWAYS discharge filter capacitors in power supplies and disconnect the power when
making resistance or diode tests.
• ALWAYS turn off the power and disconnect the test leads before opening the doors to
replace the fuse or batteries.
• NEVER operate the meter unless the back cover and the battery and fuse doors are in
place and fastened securely.

2. SAFETY SYMBOLS

This symbol adjacent to another symbol, terminal or operating device
in d ic a te s that the operator must refer to an explanation in the
Operating In s tr uc t ions to avoid personal injury or damage to the
meter
This WARNING symbol indicates a potentially hazardous situation,
WARNING
which if not avoided, could result in death or serious injury.
This CAUTION symbol indicates a potentially hazardous situation,
CAUTION
which if not avoided, may result damage to the product.
02/01/2018 Version No. 001
Compact Digital Multimeter / English
1
Tabla de contenido
loading

Este manual también es adecuado para:

161-1625

Tabla de contenido