Tabla de contenido
Idiomas disponibles

Idiomas disponibles

INSTALL HOOD

KEYHOLE (4)
1
Hang hood from (4) Mounting Screws. Slide hood towards
wall until mounting screws are engaged in narrow end of (4)
Keyholes. Tighten mounting screws securely. A long
screwdriver works best.
2
Replace bottom cover.
3
Connect ductwork to hood. Use Duct Tape to make joints
secure and air tight.
4
Install (2) PAR20, 50 W Maximum Halogen Bulbs or (2) R16,
40 W Maximum Incandescent Bulbs. Purchase bulbs
separately.
!
CAUTION:
Bulbs may be hot! Refer to bulb packaging
for further information.
5
Replace filters, turn on power at service panel, and test for
proper operation.
®
MOUNTING SCREW (4)
PAR20,
50W MAX.
HALOGEN
BULB (2)
- or -
R16,
40W MAX.
INCANDESCENT
BULB (2)
OPERATION
Fan and Lights: 3 push button switches for each. Push any button
to select one of 3 fan speeds or one of 3 light levels. Push the
same button to turn fan or light off. Press another button to change
fan speed or light level. A light above each fan button indicates the
fan speed.
Heat Sentry: Your range hood is equipped with the Heat Sentry
feature, which monitors temperature. The Heat Sentry will auto-
matically turn the fan on at its highest speed when the tempera-
ture is above normal.
1) If a fan setting is selected when the Heat Sentry in on, the light
above the fan button will flash on and off.
2) If the fan setting is off when the Heat Sentry is on, the light above
fan button 3 will flash on and off rapidly.
After the temperature has lowered to normal, the fan will change
to the setting prior to the Heat Sentry turning on.
Fuse: The hood control contains a fuse to protect it from power
surges. If the fuse has opened (blown), the green fan-level indica-
tors will operate properly when the fan buttons/switches are
DUCT
pressed - but the fan and lights will not turn on.
TAPE
The fuse is a 5 x 20 mm, 10 Amp, Fast-Acting, 125V (min.). Com-
mon manufacturer and part numbers are: Littlefuse, 217010;
Bussmann, GMA10A; Wickmann, 1942100. Radio Shack, Digikey
(1-800-344-4539), and most electronic supply stores have them
in stock.
To replace the fuse:
1.
Disconnect power at service entrance.
2.
Remove filters, bottom panel, light wire harness, and air chute.
3.
Remove and inspect fuse. If it is not open (blown), additional
diagnostics need to be done.
4.
Install new fuse.
5.
Re-assemble air chute, light wire harness, bottom panel, and
filters.
6.
Turn on power and check hood/control operation.
CLEANING
WARNING: To reduce the risk of electric shock, dis-
connect from power supply before cleaning.
Aluminum mesh filters: Clean frequently using hot water and a
mild detergent. Filters are dishwasher safe.
Charcoal filters: Clean filter surfaces frequently with a damp cloth
and a mild detergent. DO NOT immerse filters in water or put in
dishwasher. The special "Clean Sense" feature indicates when
the filter is to be replaced. The blue and yellow strips will blend to
green when it is time to change the filter. The "Clean Sense"
feature works best when facing toward the cooking surface.
To clean hood: Remove filters. Use a damp cloth and a mild deter-
gent to wipe all grease-laden surfaces. Read the Silverstone
label on the bottom cover. It has instructions for care and cleaning
of the Silverstone
- it must not become bent or misaligned. DO NOT ALLOW WATER
TO ENTER MOTOR. Make sure all surfaces are completely dry
before re-installing filters and restoring power.
Motor is permanently lubricated. Do not oil or disassemble motor.
ALLURE
RANGE HOODS
®
surface. Use care when cleaning blower wheel
®
WS2 SERIES
Page 5
®
Tabla de contenido
loading

Tabla de contenido