Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

WhispAire
WA6500 SERIES
IMPORTANT SAFETY INSTRUCTIONS
WARNING – TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK,
OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock service panel to prevent power from being
switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a quali-
fied person(s) in accordance with all applicable codes and stan-
dards, including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent backdrafting. Follow the heating equipment
manufacturer's guideline and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), and the local code authori-
ties.
5. When cutting or drilling into wall or ceiling, do not damage elec-
trical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. To reduce the risk of fire, use only metal ductwork.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
1. Never leave surface units unattended at high settings. Boilovers
cause smoking and greasy spillovers that may ignite. Heat oils
slowly on low or medium settings.
2. Always turn hood ON when cooking at high heat or when cook-
ing flaming foods.
3. Clean ventilating fans frequently. Grease should not be allowed
to accumulate on fan or filter.
4. Use proper pan size. Always use cookware appropriate for the
size of the surface element.
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT
OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOW-
ING*:
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or
metal tray, then turn off the burner. BE CAREFUL TO PRE-
VENT BURNS. If the flames do not go out immediately, EVACU-
ATE AND CALL THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN - You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels - a
violent steam explosion will result.
4. Use an extinguisher ONLY if:
A. You know you have a Class ABC extinguisher, and you
already know how to operate it.
B. The fire is small and contained in the area where it started.
C. The fire department is being called.
D. You can fight the fire with your back to an exit.
* Based on "Kitchen Firesafety Tips" published by NFPA.
Range Hood
INSTALLATION INSTRUCTIONS
READ & SAVE THESE INSTRUCTIONS!
IMPORTANT SAFETY INSTRUCTIONS
1. For general ventilating use only. Do not use to exhaust haz-
ardous or explosive materials and vapors.
2. To reduce the risk of fire or electrical shock, this range hood
should not be used with an additional speed control device.
3. To reduce the risk of shock, disconnect power before servicing.
4. To reduce the risk of fire and to properly exhaust air, be sure to
duct air outside.
PLAN THE INSTALLATION
Recommended mounting height is 18" to 24" from the bottom of
the range hood to the top of the cooking surface.
The hood should be mounted to the bottom of a standard wall
cabinet. If the hood must be mounted directly to a wall, secure the
hood to wall studs.
All wiring must comply with local codes and the unit must be prop-
erly grounded. The hood is connected to a 110-120vAC lighting
circuit (15 amp) in the circuit breaker or fuse box.
This range hood is "Convertible" – it may be installed as a ducted
or as a non-ducted unit.
IF THE RANGE HOOD IS TO BE NON-DUCTED:
• Purchase non-ducted (duct-free) charcoal filter Model BPQTF.
IF THE RANGE HOOD IS TO BE DUCTED:
• Ductwork can be installed vertically or horizontally.
• Duct runs should be as short as possible.
• Avoid the use of elbows.
• Use duct tape at all joints.
• Do not use duct smaller than the discharge on the hood.
• For 7" round ductwork installation, use 7" round damper, Model
895 (purchased separately).
loading

Resumen de contenidos para NuTone WhispAire WA6500 Serie

  • Página 1 INSTALLATION INSTRUCTIONS READ & SAVE THESE INSTRUCTIONS! ™ WhispAire Range Hood WA6500 SERIES IMPORTANT SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS 1. For general ventilating use only. Do not use to exhaust haz- WARNING – TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, ardous or explosive materials and vapors.
  • Página 2 HORIZONTAL DISCHARGE THROUGH WALL WALL SUPPLIED DUCT WALL CAP TRANSITION (Model 838AL) RANGE HOOD FIGURE 1 ROOF CAP VERTICAL DISCHARGE USING 3¼” x 10” DUCT CUTOUT DIMENSIONS 1" ELBOW EAVE CAP (Model 836AL) VIEW 3¼" x 10" 12" 9" DUCT "...
  • Página 3 PREPARATION LOCATORS 1. Use the dimensional drawings (Refer to FIGURES 1 - 3) to lay BAFFLE PLATE out the range hood’s mounting holes, wiring access and ductwork by marking the cabinet bottom and drywall where applicable. 2. Make cutouts for wiring and ductwork. 3.
  • Página 4 REPLACEMENT PARTS Should replacement parts be required, please indicate hood model number and appropriate part number. Contact your NuTone dealer or write to NuTone: Attn: Parts Department NuTone, Inc.
  • Página 5 SERVICE PARTS KEY NO. PART NO. DESCRIPTION 99080532 Motor R99020277 Fan Blade R99420635 External Hitch Pin (Hairpin) 99271236 Lamp Socket (2 Required) R99030319 Fan Switch Assembly R561138 Light Switch K4402-000 Rectifier Assembly (Night-Light) 97015294 Light Lens Assembly 98009816 Wiring Cover R99091038 Grille (Black) R99091039...
  • Página 6 IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICU- LAR PURPOSE. During this one-year period, NuTone will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service.
  • Página 7 INSTRUCCIONES DE INSTALACION ¡LEA Y GUARDE ESTAS INSTRUCCIONES! ™ WhispAire Campana de Cocina SERIE WA6500 INSTRUCCIONES IMPORTANTES INSTRUCCIONES IMPORTANTES DE SEGURIDAD DE SEGURIDAD CUIDADO – PARA REDUCIR EL RIESGO DE FUEGO, DESCAR- 4. Use un extinguidor SOLAMENTE si: GA ELECTRICA, O LESIONES A PERSONAS, OBSERVE LO A.
  • Página 8 DESCARGA HORIZONTAL A TRAVES DE LA PARED PARED DIMENSIONES DE LA SALIDA ARMARIO TRANSICION DE COCINA PROVISTA PARA TAPA DE PARED EL CONDUCTO (Modelo 838AL) 17,78 CAMPANA DE COCINA 1,91 cm 9,84 cm ORIFICIO PARA 13,34 EL CABLEADO 26,67 FIGURA 1 TAPA E TECHO DESCARGA VERTICAL USANDO (Modelo 634 o 644)
  • Página 9 PREPARACION LOCALIZADORES 1. Use los dibujos dimensionales (FIGURAS 1 - 3) para disponer PLACA los orificios de montaje de la campana, acceso del cableado y DEFLECTORA conductos, marcando el fondo del armario y el tabique donde sea aplicable. 2. Efecto e los cortes para el cableado y el conducto. 3.
  • Página 10 PIEZAS DE REPUESTO Indique por favor el número correcto de la pieza, si requiere piezas de repuesto. Consulte con sus distribuidores NuTone o escriba a NuTone: Attn: Parts Dept.
  • Página 11 PIEZAS DE SERVICIO CODIGO NO. PIEZA DESCRIPCION 99080532 Motor R99020277 Aspa del ventilador R99420635 Perno Sujetador Externo 99271236 Portalamparas (2 requeridos) R99030319 Ensamblado de interruptor del ventilador R561138 Interruptor para luz K4402-000 Ensamblado del rectificador (Luz nocturna) 97015294 Ensamblado del lente de luz 98009816 Cubierta para el alambrado R99091038...
  • Página 12 O IMPLICITAS, INCLUYENDO, PERO NO LIMITADAS A, GARANTIAS IMPLICITAS DE COMERCIALIZACION O APTITUD PARA UN PROPOSITO PARTICULAR. Durante el período de un año, y a su propio criterio, NuTone reparará o reemplazará, sin costo alguno cualquier producto o pieza que se encuentre defectuosa bajo condiciones normales de servicio y uso.