PRECAUTIONS
IMPORTANT- The input voltage of the Ultrasonic Bath transducers can reach hundreds of
volts. Therefore, it is very important to observe the following Safety Regulations:
1) Do not open the lid when the power cord is connected to the power supply.
2) Do not spill water or any other conducting fluid over the unit's housing.
3) Always connect the unit to grounded power outlets.
 Connect the unit to a grounded 230 V, 50/60 Hz power outlet.
 Do not use inflammable solvents as cleaning solutions.
 Keep the unit unplugged before filling it. Do not fill the tank above the max. mark. Do not start up the unit
when the water level is below the min. mark.
 Do not allow children or unskilled people to handle the unit.
 Never submerge the unit in any liquid to clean it.
 Ultrasonic cleaning is not suitable for organic pearls.
 Do not open the unit while it is connected to the power supply.
 The machine lid may be hot after a cycle. Proceed with caution when removing it.
 If you are not sure of the effects of the cleaning solution on a given type of item, carry out a previous test
with a single item.
 Do not attempt to remove any screw or panel. The user does not need to manipulate anything inside.
 To prevent electric shock, never touch the power cord or socket with wet hands.
 Never operate the unit if the plug or the power cord is damaged. If the unit does not work properly, is
damaged or has fallen into the water, refer it to a technical service for examination and repair.
 Do not touch the unit if it has fallen into the water. Unplug it immediately.
 Use the unit properly according to the user's guide. Do not use accessories not recommended by the
manufacturer.
 The unit should never be left unattended when it is plugged.
 Do not operate the unit next to heat sources such as radiators.
 Install the unit on a dry and flat surface.
Be careful that water does not enter through the ventilation slots. It could damage the electronic
circuits.
DIRT REMOVING PROCESS
The ultrasounds generate
myriads of small bubbles.

CLEANING SOLUTIONS

Cleaning solutions can be classified into two types: those consisting of a cleaning solution mixed with water,
and solvents.
The most common cleaning method is with water, as it has an acceptable capacity to dissolve inorganic
substances. However, it is extremely limited in dissolving organic substances. For this type of compound,
The ultrasounds make the
bubbles implode constantly
and
impact
against
object's surface
The impact breaks up the dirt
into
many
the
separates
object's surface. The grains
remain in the water.
grains
and
them
from
the