EQUATION EQI-80R Instrucciones Para Instalación, Uso Y Mantenimiento página 20

Insertable
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 1
2. REMOVING THE FANS
2.1. WIRING AND ELECTRIC COMPONENTS
8. Right-hand fan
9. Switch
10. Connection strip
11. Resistance
12. Thermostat
13. Insulating washer
14. Ceramic fibre insulation
2.2. REMOVING FANS
ATTENTION! BEFORE WORKING ON THE FANS, MAKE SURE THAT THE UNIT IS NOT CONNECTED TO
ANY ELECTRIC POWER SUPPLY.
In order to replace the fans, observe the following instructions:
1, Free the screw (1) that holds the cast iron grid (2) to the front section (5).
2. Remove the two screws (3) that hold the fan (4) to the back sheet (6).
To install the fans follow the same steps in the opposite order.
IMPORTANT! MAKE SURE TO CONNECT THE ELECTRIC TERMINALS AS THEM CAME FROM THE
FACTORY, BEFORE INTRODUCING THE FAN IN ITS FINAL POSITION.
1
2
I Red
Yellow-green
0 Blue
Blue
II Black
Brown
3 4
7
6
5