Grounding Instructions - Speedaire 1NNF4 Instrucciones De Operación

Ocultar thumbs Ver también para 1NNF4:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Speedaire Operating Instructions
Speedaire
Compressors
Assembly (Continued)
E

GROuNDING INSTRuCTIONS

N
1. This product must be grounded.
G
In the event of an electric short
L
circuit, grounding reduces the risk
I
of electrical shock by providing an
S
escape wire for the electric current.
H
Unit is equipped with a cord that has
a grounding prong. It will fit one of
the common outlet types shown in
Figure 9. If plug will not fit in the
desired outlet, have the outlet
replaced by a qualified electrician.
Ground Pin
120V
15A
120V
20A
Grounded Outlet
Figure 9
Improper
use of
grounding plug can result in a
risk of electrical shock.
NOTE: Do not use
grounding adapter.
2. If repair or replacement of the cord or
plug is necessary, do not connect the
grounding wire to either flat blade
terminal. The wire with insu
lation having an outer surface that is
green with or without yellow stripes is
the grounding wire.
3. Check with a qualified electrician
or serviceman if the grounding
instructions are not completely
understood, or if in doubt as to
whether the product is properly
grounded. Do not modify the plug
provided; if it will not fit the outlet,
have the proper outlet installed by a
qualified electrician.
Portable Air
®
PLuGS AND RECEPTACLES
1. If the plug on the electrical cord of the
unit is unfamiliar to you or will not
fit your particular receptacle, Figure
9 will help you understand why by
illustrating the different plugs and the
voltages they are to be used with.
2. Make sure that the product is
connected to an outlet having the
same configuration as the plug.
3. The receptacles must be connected
to circuits rated to carry at least the
voltage and amperages shown.
4. NEVER have a receptacle replaced
Ground Pin
with one of a higher amperage
before determining the change can
240V
be made according to all electrical
15A
codes affecting your particular area.
240V
The installation should be made
20A
by a qualified electrician. If the
Grounded Outlet
products must be reconnected for
use on different types of circuits, the
re-connection should be made by
qualified personnel.
DuAL vOLTAGE MOTORS (SOME
MODELS)
Check motor decal to change from low
voltage to high voltage.
qualified electrician.
To change connections for alternate
voltage:
1. Disconnect cord from power source
2 . Remove motor terminal cover.
3 . Find connection diagram on back side
of the cover or on motor nameplate
and reconnect to desired voltage as
indicated on diagram.
wiring diagram you must find a qualified
electrician that does understand wiring
diagrams.
4 . Change plug to match voltage and
current requirements.
be sure the green ground wire of the
cord connects to the ground pin of
the plug and to the metal body of the
pressure switch.
Operation
START-uP
with oil before startup. See Lubrication
section.
the hose until start-up is completed and
the unit checks OK.
1. Remove the dipstick breather and
fill pump to the proper oil level. See
Lubrication Section.
2. Turn regulator knob clockwise to
open air flow.
3. Turn pressure switch lever or knob to
OFF position and plug in power cord.
4. Turn pressure switch lever or knob to
AUTO position and run unit for 30
minutes to break in the pump parts
(See Figure 10).
All wiring must be
performed by a
If you do not
understand this
Figure 10
6
When converting to
an alternate voltage,
This compressor
pump must be filled
Do not attach air
tools to open end of
Off
Auto