11. Wall Control Installation
11.3
Before installing the SW605 wall control, place the SW605
wall control in "OFF" mode by pushing "ON/OFF" switch to
11.4
the "OFF" position.
Connect one black wire of the SW605 wall control to the
"hot" wire. Securely connect wires with wire connectors
11.5
supplied (Figure 34).
Connect one black wire of wall switch to the "load" (black)
wire in wall box. Securely connect wires with wire
connector supplied.
WARNING
!
Do not connect any neutral (white) wire to this control.
Incorrect wiring will damage this control.
11.6
Screw the SW605 wall control into wall box using the
supplied screws. Leave the SW605 wall control in "OFF"
mode until fan installation is completed.
WARNING
!
Check to see that all connections are tight and that no
bare wires are visible at the wire connectors.
11.7
The SW605 wall control is supplied with a white, ivory, and
almond color switch covers. Choose the finish that best
suits your needs and snap the cover onto the SW605 wall
11.8
control (Figure 34).
Install decorator wall plate using the two screws provided
with wall plate. Leave the SW605 wall control in "OFF"
mode until fan installation is completed (Figure 34).
(Continued)
SCREWS (2)
SWITCH COVER
DECORATIVE WALL PLATE
Figure 34
20
SW605 FAN/LIGHT
WALL BOX
WALL CONTROL
C
NEUTRAL
WIRES
E.T.L. Model No.: CF985