6. Using the product

D
The product is fitted with a main on/off pushbutton (A), a slider to select desired
working function (B), a slider to set wished temperature (C) and a led showing the
operating status (D).
The main pushbutton (A) controls the supply of the entire product. When switched
on the internal electronics is ready to be used. In case you have the optional
remote control we suggest to use this button only in case you will not use the pro-
duct for al long period, in all other cases is preferable to use the selector (B).
Switching off the product by the pushbutton (A) causes, after about 3 hours of
internal autonomy, the loss of time/day information blocking the programmed
functioning until further data input.
The main pushbutton (A) deactivates the product apart of any possible input
coming from the pilot wire.
Slider selector (B) allows to select between one of the following working set:
STAND-BY
The product is supplied but heating elements are disconnected.
COMFORT
The product is supplied and works depending on the temperature
(C).
ECO
The product is supplied and works depending on the temperature set with the slider
(C) decreased of 3,5°C.
FROST-FREE
The product is supplied and thermostat set is electronically forced to 7±3°C
(independently of tem perature set with the slider (C)).
PROG
Functioning depends on inputs coming from the pilot wire (black) or from the
optional remote control.
The thermostat (C) maintains the required ambient temperature by automatically
turning the appliance on and off. The more the knob is moved to the right, the hig-
her the temperature will be. The highest position of the thermostat corresponds
to approximately 30°C, the bottom one to about 10°C.
To set optimum combination between room temperature and power consumption
a specific range of the thermostat has been highlighted as "comfort".
In case you need a frost free selection we suggest to use the function selector (B)
and set it to the " " position, without moving the thermostat (C) to the minimum.
C
B
14
A
set with the slider
Tabla de contenido