Trouble shooting

Fault
Compressor is not run-
ning, and the ice packs
are not cold
Compressor is running,
and the temperature is
too high
No temperature is
displayed
Temperature goes
below +2°C in a spe-
cific basket
Possible cause
Be patient, it is most likely that the
compressor will start within a few
minutes.
The ventilation grille is blocked.
The lid is not closed properly.
The temperature in the room in which
the appliance is installed is too high.
The thermometer is broken.
There is not enough light for the solar
sensor.
Air circulation is restrickted.
Basket in direct contact with wall.
Remedy
If this is not the case, check the fol-
lowing:
- Check that power is connected.
- Check the fuse and replace it if
necessary.
- If the above is OK, call technical
supervisor.
Ensure unhindered air circulation.
Ensure that the lid is closed properly.
Shield the appliance against direct
sun light and ensure more ventilation
to the room.
Change the thermometer.
Turn on the light.
Check load hight is not above 250mm
(or loadline) in lower baskets.
Move the end basket a little to leave
a gap between the basket and the
wall.