Product Life Cycle Handling; Transport; Packaging; Storage - Kollmorgen AKD 2G Manual Del Usuario

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 43
AKD2G Safety Notes | 1   English

1.2 Product life cycle handling

1.2.1 Transport

Transport the AKD2G in accordance with IEC 61800-2 as follows:
Transport only by qualified personnel in the manufacturer's original recyclable packaging.
NOTICE: Avoid shocks while transporting.
Vibration/Shock: AKD2G is tested for environmental class 2M1 of IEC 60721-3-2.
Store at or below maximum stacking height 8 cartons (see "Storage" (➜ # 8))
Transport only within specified temperature ranges:
-25 to +70 °C, max. rate of change 20 K/hour, class 2K3.
Transport only within specified humidity:
max. 95% relative humidity at +40°C, no condensation, class 2K3.
The drives contain electrostatically sensitive components that can be damaged by incorrect
handling. Electrostatically discharge yourself before touching the drive. Avoid contact with
highly insulating materials, such as artificial fabrics and plastic films. Place the drive on a
conductive surface.
If the packaging is damaged, check the unit for visible damage. Inform the shipper and the
manufacturer of any damage to the package or product.

1.2.2 Packaging

The AKD2G packaging consists of recyclable cardboard with inserts and a label on the out-
side of the box.
Model
AKD2G-Sxx-6V03 to 6V12
AKD2G-Sxx-7V03 to 7V12
Mating connectors are not included in the package of a standard drive.
Mating connectors are included when the drive is ordered with accessories (append "-A" to
the model number).

1.2.3 Storage

Store the AKD2G in accordance with IEC 61800-2 as follows:
Store only in the manufacturer's original recyclable packaging.
Store at or below maximum stacking height 8 cartons.
Store only within specified temperature ranges: -25 to +55 °C, max.rate of change
20 K/hour, class 1K4.
Storage only within specified humidity: 5 to 95% relative humidity, no condensation, class
1K3.
Store in accordance with the following duration requirements:
8
Kollmorgen | kdn.kollmorgen.com | February 2020
Less than 1 year: without restriction.
More than 1 year: capacitors must be re-formed before setting up and operating the
drive. Re-forming procedures are described in the KDN (Forming).