Stop screw
Manufactured by:
Emerson Process Management
El-O-Matic B.V.
Asveldweg 1
7556 BT Hengelo (Ov.)
The Netherlands
DOC.SVM.1 Rev: A
Installation and setting instructions
8
Maintenance
Hyvision switch boxes require no servicing during
their normal working life. In the event of failure
replace parts only with HYTORK supplied
components. In an emergency replace the
complete switch box.
Be sure to disconnect all air and electrical supplies
before starting any dismantling or maintenance on
the actuator or switchbox.
Repair of this equipment shall be carried out by
suitably trained personnel in accordance with the
applicable code of practice e.g. EN 60079-19.
The top and bottom bearings are designed for 5
million operations. If this is expected to be
exceeded, the user should introduce routine
maintenance to check that the bearing clearance
does not exceed 0.12 mm.
Components to be incorporated into or used as
replacement parts of the equipment shall be fitted
by suitably trained personnel in accordance with the
manufacturer's documentation.
5
SafeVision Switchbox
March '04