CAME ZVL370.01 Manual De Instrucciones página 20

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

DISPLAY
1
2
3
4
5
6
7
All rights reserved. Unauthorised copying or use of the information contained in this document is punishable by law
8
9
0
A
b
All rights reserved. Unauthorised copying or use of the information contained in this document is punishable by law
C
*
Travel direction inversion only active during the closing stage.
** The indicator light flashes slowly during opening, quickly during closing, remains open when the gate is not
completely closed, and is off when the gate is completely closed.
*** If the photoelectric cell is in alarm and the gate is blocked no movement commands will be accepted
(not even in the opening direction).
B) Programming the deceleration times
9
10
Pressing the "PROG" button will set the value on the display: to change this value press "SEL", and then press
"PROG" again. When the symbol
next programming stage. If instead you wait for 20 seconds the programmer will save the parameters set up
to now and leave the programming mode.
DM0488
Description :
PROGRAMMAZIONE FIG 9
The deceleration time may be selected from the following values:
PRG852-FIG.9
PRG852
Date :
P.J.Heath
24-05-2000
= 3 second
The choice should be made to enable a smooth stop with slow speed only being used where absolutely
necessary.
DM0490
Description :
PROGRAMMAZIONE FIG 10
WARNING! The
PRG852
PRG852-FIG.10
during which the electrical sensor works as a travel limit in the last few seconds of movement must be decided
P.J.Heath
Date :
24-05-2000
upon. You are advised to set a time of 4,5 seconds.
FIXED NUMBER
Single motor
Hinged gates
Binding posts 7,8: night light
Electric locking device enabled
TD: open-close (*)
Automatic reclosing enabled
Preflashing enabled
Motor 1 travel limit enabled
Motor 2 travel limit enabled
Warning lights with onboard electronics
Deceleration enabled
Non flashing indicator light
FTC_I enabled even with gate blocked (***)
9a
10a
appears on the display pressing the "PROG" button will move on to the
Description :
PROGRAMMAZIONE FIG 9a
PRG852-FIG.9a
= 4,5 seconds
Description :
PROGRAMMAZIONE FIG 10a
,
,
PRG852-FIG.10a
Pressing the "PROG" at the point described in fig. 8 will allow you
to set the deceleration times.
The values range from 1 to 3, and the value shown in the figure is
relative to the minimum setting (the following characters will alternate
on the display
and
Each time the "SEL" button is pressed the value will increase by 1;
once you arrive at
the symbol , pressing "SEL" again will cycle back to . The indication
on the display will be alternating if a value has not been selected and will
be fixed when you arrive at a previously selected value.
= 6 seconds
selection must be carried out even if deceleration is excluded: The time
20
FLASHING NUMBER
Two motors
Sliding gates
Binding posts 7,8: CH2 control contact
Electric locking device disabled
TD: open-block-close-block
Automatic reclosing disabled
Preflashing disabled
Motor 1 travel limit disabled
Motor 2 travel limit disabled
Warning lights activated by PRG
Deceleration disabled
Flashing indicator light (**)
FTC_I enabled only during closing
).
the next time you press "SEL" the display will show
Tabla de contenido
loading

Este manual también es adecuado para:

Ypr8522cc