Load Defaults; Last Fault; Priming Speed And Duration - Zodiac JEP-R Manual De Instalación Y Operación

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Page 14
ENGLISH
To set the minimum speed, from the service setup menu,
select SET MIN LIMIT using the arrow keys. Press MENU.
Using the arrow keys, set the minimum speed to the desired
value. Press MENU to accept and store.
SET MIN LIMIT
RPM: 600
2
MENU
To set the maximum speed, from the service setup menu,
select SET MAX LIMIT using the arrow keys. Press MENU.
Using the arrow keys, set the maximum speed to the desired
value. Press MENU to accept and store.
SET MAX LIMIT
2
MENU
4.3

Load Defaults

To restore factory default settings to the controller, from
the service setup menu, select LOAD DEFAULTS. Press
MENU. Using the arrow keys, select YES. Press MENU to
restore factory default settings.
LOAD DEFAULTS
2
MENU
Default Speeds
eStar
Speed 2 - 8
Priming Speed
Other Defaults
Freeze Protect Duration
Priming Duration
ePump™ and VS-FloPro™ Variable-Speed Pump Controller
3
4
RPM: 3450
4
3
YES
4
3
1750 RPM
2750 RPM
2750 RPM
30 min
3 min
4.4

Last Fault

This feature shows on the top display line, the most recent
unique fault message and on the bottom display line, the
second-to-last unique fault message. If there is no entry
for a fault, the display will show "*----------------*" on the
corresponding line. To select last fault, from the service setup
menu select LAST FAULT. Press MENU.
NOTE
The fault messages are stored in non-volatile
memory, and remain even with no power. To clear the
fault history, press either arrow key.
SELECT SERVICE SETUP
2
MENU
4.5

Priming Speed and Duration

The controller will command the variable-speed pump
to operate at the priming speed for the priming duration
specified (except during timer program overlaps or follow-on
commands where the pump is not stopped before changing
speeds). From the service setup menu, select PRIMING using
the arrow keys. Press MENU.
PRIMING DURATION
2
MENU
To set priming speed, select PRIMING SPEED using the
arrow keys. Press MENU. Using the arrow keys, set the
priming speed to the desired value. Press MENU to accept
and store.
PRIMING SPEED
2
|
Installation Manual
LAST FAULT
3
4
MIN: 3
3
4
RPM: 3450
4
3
MENU
Tabla de contenido
loading

Tabla de contenido