PERFORMANCE
Model
60013/61013/
60043/61033
60023/61023
60033
62013
62023/62033
SAFETY INSTRUCTIONS
1.
Do not pump flammable or explosive liquids such as oil, gasoline, kerosene, ethanol, etc. Do not use in the
presence of flammable or explosive vapors. Using this pump with or near flammable liquids can cause an explosion
or fire, resulting in property damage, serious personal injury, and/or death.
2.
ALWAYS disconnect the power to the pump before servicing.
3.
Do not touch the motor housing during operation. The motor is designed to operate at high temperatures. Do not
disassemble the motor housing.
4.
Do not handle the pump or pump motor with wet hands or when standing on a wet or damp surface, or in water.
5.
Wear safety goggles at all times when working with pumps.
6.
This is a dual voltage 115/230 V pump. VOLTAGE SELECTOR INSIDE PRESET TO 230V. For 115V selection,
please open the terminal cover and set the switch to the proper voltage. All wiring should be performed by a
qualified electrician.
7.
Protect the electrical cord from sharp objects, hot surfaces, oil, and chemicals. Avoid kinking the cord. Do not use
damaged or worn cords.
8.
Failure to comply with the instruction and designed operation of this unit may void the warranty. ATTEMPTING TO
USE A DAMAGED PUMP can result in property damage, serious personal injury, and/or death.
9.
The pump should be connected to a 230V/115V,GFCI outlet protected with a 10 amp(230V)/20 amp(115V) fuse or
circuit breaker.
10. Know the pump and its applications, limitations, and potential hazards.
11. Secure the pump to a solid base.
12. Periodically inspect the pump and system components. Disconnect the pump from the power supply before
inspecting.
13. Follow all local electrical and safety codes, along with the National Electrical Code (NEC). In addition, all
Occupational Safety and Health Administration (OSHA) guidelines must be followed.
14. The motor of this pump has a thermal protector that will trip if the motor becomes too hot. The protector will reset
itself once the motor cools down and an acceptable temperature has been reached. The pump may start
unexpectedly if it is plugged in.
15. Ensure the electrical power source is adequate for the requirements of the pump.
16. This pump is made of high-strength, corrosion-resistant materials. It will provide trouble-free service for a long time
when properly installed, maintained, and used. However, inadequate electrical power to the pump, dirt, or debris
may cause the pump to fail. Please carefully read the manual and follow the instructions regarding common pump
problems and remedies.
Discharge Pressure of 40 psi
HP
0 ft.
5 ft.
1/2
7.2
6.5
3/4
9.2
9.0
1
14.0
12.6
3/4
5.8
5.4
3/4
7.4
6.7
GPM of Water @ Total
10 ft.
15 ft.
6.0
5.5
8.1
7.4
12.0
10.5
5.0
4.6
6.3
5.9
2
Max. Pressure
20 ft.
25 ft.
5.0
4.5
6.8
5.8
9.2
7.0
4.2
4.0
5.4
4.9
shutoff
66PSI
67PSI
67PSI
66PSI
66PSI