PERFORMANCE
Model
HP
70042
2
70033/70036
1-1/2
70023/70026
1
70013/70016
3/4
SAFETY INSTRUCTIONS
1.
Do not pump flammable or explosive liquids such as oil, gasoline, kerosene, ethanol, etc. Do not use in the
presence of flammable or explosive vapors. Using this pump with or near flammable liquids can cause an explosion
or fire, resulting in property damage, serious personal injury, and/or death.
2.
ALWAYS disconnect the power to the pump before servicing.
3.
Do not touch the motor housing during operation. The motor is designed to operate at high temperatures. Do not
disassemble the motor housing. To avoid burns when servicing pump, allow it to cool for 20 minutes after shut-down
before handling.
4.
Do not handle the pump or pump motor with wet hands or when standing on a wet or damp surface, or in water.
5.
Wear safety goggles at all times when working with pumps.
6.
For model 70013/70023/70033/70016/70026/70036, is a dual voltage 115/230V pump. For model
70013/70023/70033, voltage selector inside preset to 230V. For 115V selection, please open the motor end cover
and set the switch to proper voltage. For 70016/70026/70036, this pump is built- in automatic dual-voltage selector
switch and voltage can be converted by automatically. For model 70042 is 230 Volts only. All wiring should be
performed by a qualified electrician.
7.
Protect the electrical cord from sharp objects, hot surfaces, oil, and chemicals. Avoid kinking the cord. Do not use
damaged or worn cords.
8.
Ensure the electrical power source is adequate for the requirements of the pump.
9.
Failure to comply with the instruction and designed operation of this unit may void the warranty. ATTEMPTING TO
USE A DAMAGED PUMP can result in property damage, serious personal injury, and/or death.
10. The pump of 1 HP& 3/4 HP & 1-1/2 HP should be connected to a 230V/115V GFCI outlet protected with a 20
amp(230V)/30 amp(115V) fuse or circuit breaker. The pump of 2 HP should be connected to a 230V GFCI outlet
protected with a 20 amp (230V) fuse or circuit breaker.
11. Know the pump and its applications, limitations, and potential hazards.
12. Secure the pump to a solid base.
13. Periodically inspect the pump and system components. Disconnect the pump from the power supply before
inspecting.
14. Follow all local electrical and safety codes, along with the National Electrical Code (NEC). In addition, all
Occupational Safety and Health Administration (OSHA) guidelines must be followed.
15. The motor of this pump has a thermal protector that will trip if the motor becomes too hot. The protector will reset
itself once the motor cools down and an acceptable temperature has been reached. The pump may start
unexpectedly if it is plugged in.
16. This pump is made of high-strength, corrosion-resistant materials. It will provide trouble-free service for a long time
when properly installed, maintained, and used. However, inadequate electrical power to the pump, dirt, or debris
may cause the pump to fail. Please carefully read the manual and follow the instructions regarding common pump
problems and remedies.
2
GPM of Water @ Total Discharge Pressure of 30 psi
5 ft.
10 ft.
47
45
45
42
31
28
25
22
15 ft.
20 ft.
42
39
39
35
24
20
18
15
For Professional Technical Support call 1-844-242-2475
Voltage
Max. Pressure
230
50 PSI
230/115
49 PSI
230/115
44 PSI
230/115
40 PSI