Ignition of the main burner and temperature regulation (Picture A)
After releasing the button (14), the gas enters into the safety valve.
Turning the graduated konb
, the gas flows into the main burner (3) which ignites.
Turning off the main burner (Picture A)
Turn the knob (14) to the ? ? position. Only the flame of the pilot burner will remain lighted.
Turning off the appliance (Picture A)
Press and turn the knob (14) into position "0". This command blocks the gas flow in both the main burner and the pilot burner.
TANK FILLING (Picture A)
Turn and load cock lever (C) from the off position
to the position
untill the water in the tank gets the level indicated by the symbol

EMPTYING THE TUB

The user should have a suitable container for emptying the water, heat
resistant and made in such a way that the water doesen't overflow and
become a danger during the empying.
Insert the drainage pipe according to the drawing and position the
container.
Push the security device upwards againsts the automatic openings (A)
and turn the lever (B) to the symbol
Note: Keep attentio to the distance from the appliance and the corners
of the support.
Note: The procedure should be done with cold water.
INSTRUCTIONS FOR REMOVAL OF EXHAUST GASES
Type "A" Appliances (See Data Plate)
Combustion fumes from type " A" appliances must be removed byfspecial hoods or similar devices connected to an efficient
flues or directly to the outside (natural removal).Picture 1.
If this is not possible, an extraction fan may be used connected directly to the outside (mechanical removal). Pisture 2.
The capacity of the fan shall not be inferior to what mentioned by 4.3 point of the UNI-CIG 8723 regulation.
Mechanical Removal of Exhaust Gases
The supply of the gas to the appliance must be directly linked to the exhaust removal system be cut off if the system capacity
goes below the values of the 4.3 point of the UNI-CIG 8723 regulation.
The supply of the gas to the appliance must be done again manually.