Trouble Shooting - Gaggenau VG 491 Instrucciones De Uso

Ocultar thumbs Ver también para VG 491:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Trouble shooting

Malfunctions often have simple explanations. Please
read the following notes before calling the after-sales
service.
Malfunction
Burner does not ignite when
switched on.
Burner does not ignite when
switched on. Audible signal
sounds.
Burner goes off during operation.
Audible signal sounds.
Burner goes off during operation.
Audible signal continues to
sound although all control knobs
have been turned to 0.
Burner goes off during operation. Power failure
Turn the control knob to 0. The
appliance tries to reignite and an
audible signal sounds.
Burners go off during operation.
An audible signal sounds.
There is a smell of gas in the
kitchen.
The corners of the appliance
curve upwards slightly during
operation.
Cause
No power supply.
Fault on the burner or the gas sup-
ply.
Fault on the burner or the gas sup-
ply.
Protection against overheating
Technical defect
Safety shut-off: appliance has not
been operated in the past six hours.
Potential leak on connection of gas
cylinder.
The heat causes the cooktop's
metal to expand.
m
Risk of electric shock!
Incorrect repairs are dangerous. Repairs may only be
carried out by one of our trained after-sales engineers.
If the appliance is faulty, unplug the mains plug or
switch off the fuse in the fuse box. Contact the after-
sales service.
Solution
Turn all control knobs to 0. Check in the fuse box
whether the fuse has blown.
Turn all control knobs to 0.
Check:
Burner parts fitted correctly?
Gas shut-off valve open?
Burners dry and clean?
Air in the line after first connection or a change
of gas cylinder (liquid gas)?
Gas cylinder empty (liquid gas)?
Turn all control knobs to 0.
has cooled down.
Check:
Burner parts fitted correctly?
Electrode soiled (food remainders) or moist?
Burner soiled by spillovers?
Strong draught (e.g. open window directly
behind the gas stovetop)?
Gas cylinder empty (liquid gas)?
Turn all control knobs to 0. Wait until the appliance
has cooled down and the audible signal goes off.
Turn all control knobs to 0. Check the power supply.
The burners do not reignite automatically after a
power failure.
Notify Gaggenau customer service.
Turn the control knob to 0 and then switch on again,
if necessary.
Check gas cylinder connection for leaks.
This is normal. No curving is visible after cooling
down.
Wait until the appliance
13
Tabla de contenido
loading

Tabla de contenido