Kohler K-1737 Guia De Instalacion página 7

Ocultar thumbs Ver también para K-1737:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Steam Housing
Steam Head
Provide
clearance
from wall.
3. Install the Steam Head(s)
WARNING: Risk of scalding. Do not locate the steam head near a seat or bench, as the steam head
is hot during operation and may scald the user if touched.
NOTICE: Do not obstruct the steam head with shut-off valves, plugs, or caps.
NOTE: The steam housing can be adjusted for a wall thickness of 3/16" (5 mm) to 1-1/2" (3.8 cm) using
the adjustment screws located on the steam head housing.
Position the gasket (provided) around the base of the steam housing so the gasket is between the
wall and the lip of the steam housing.
Turn the adjustment screws on the steam housing until the distance between the back edge of the
steam housing and the head of each adjustment screw is equal to the wall thickness.
Tighten the adjustment screws securely. Do not overtighten.
Secure the steam housing to the wall by carefully tightening the hold-down screws.
Thread the steam head clockwise onto the steam housing assembly until it is hand-tight.
Turn the steam head counterclockwise until the aromatherapy well is located at the 12 o'clock
position.
Apply thread sealant tape to the 1/2" NPT male threads on the steam housing.
Push the steam housing assembly through the installation hole from inside the shower.
Complete the connection of the steam line to the steam housing.
Kohler Co.
1/2" NPT Elbow
Adjustment Screws
7
Wall
Nipple
Gasket
Steam
Housing
Lip
Hold-Down
Screw
Aromatherapy
Well
Steam Head
1069332-2-B
Tabla de contenido
loading

Este manual también es adecuado para:

K-1838

Tabla de contenido