DEFECTS AND TROUBLESHOOTING

Defect
Poor production of hot water
Low water temperature
Long reset time
Cause
- Power voltage is too high
- Capacity is too high
- Clogging and deposits in the sanitary
circuit
- Circulator operation
- Low water temperature of the
air heater combined
- Thermostat operation
- Circulator operation
- Presence of calcareous deposits the
tank
- Presence of air in the main circuit
- Low temperature of the air heater
combined
- Feeding circulator
- Presence of air in the circuit
- 27
-
USE AND MAINTENANCE
How to solve the problem
- Install a pressure limiting device
- Install a capacity reducer
- Check and clean
- Check
- Check the thermostat adjustment
and status
- Check adjustment and status
- Check
- Check and clean
- Deareate
- Check the thermostat adjustment
- Check proper operation
- Deareate