Manual release instructions

In the event of a fault or power failure, insert the key and
turn it clockwise and completely open the hatch. Manually
open the gate.
To lock the gate again, close the hatch, turn the key anticlock-
wise and remove the key.
WARNING: the gate lock and release operations
must be performed with the motor idle.
Do not enter within the operating range of the gate.
When the hatch is closed but the key is still
horizontal, the release microswitch is open and all
manoeuvres are prevented.
Technical specifications
Manufacturer:
Entrematic Group AB
Address:
Lodjursgatan 10, SE-261 44 Landskrona, Sweden
Type:
NES300EH
Power
230V~ 50/60 Hz
Power
1.2 A
Fuse
Ambient temperature
Degree of protection
Control panel
CS12E
Acoustic pressure
Certifications of third parties, supplied by accredited certification bodies and valid for us-
Certifications:
age safety. Refer to the Conformity Declaration.
Manufacturer:
Entrematic Group AB
Address:
Lodjursgatan 10, SE-261 44 Landskrona, Sweden
Type:
NES600EH
Power
230V~ 50/60 Hz
Power
1.5 A (300W)
Fuse
Ambient temperature
Degree of protection
Control panel
CS12E
Acoustic pressure
Certifications of third parties, supplied by accredited certification bodies and valid for us-
Certifications:
age safety. Refer to the Conformity Declaration.
NES300EHP
NES400EH
230V~ 50/60 Hz
230V~ 50/60 Hz
1.2 A
1.2 A
F1.6 A
-20°C
CS12M
CS12E
<70 dB(A)
NES600EHP
NES600EHJ
230V~ 50/60 Hz
120V~ 50/60 Hz
1.5 A (300W)
3 A (300W)
F2 A
F4 A
-20°C
CS12M
CS12E
<70 dB(A)
46
NES400EHP
230V~ 50/60 Hz
1.2 A
F2 A
+55°C
IP24
CS12M
NES1000EHP
230V~ 50/60 Hz
2 A (400W)
F2.5 A
+55°C
IP24
CS12M
NES400EHJ
120V~ 50/60 Hz
2.4 A
F4 A
CS12E
NES1000EHPJ
120V~ 50/60 Hz
4 A (400W)
F6.3 A
CS12M