Panasonic UA1E5 Serie Instrucciones De Operación página 13

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 26
Check the following before calling for servicing.
Check the following before calling for servicing.
Symptom
Symptom
Heating/Cooling operation is not working
effi ciently.
Heating mode cannot be operated.
Noisy during operation.
Remote control does not work.
(Wireless remote control display is dim or
transmission signal is weak.)
The unit does not work.
The unit does not receive the signal from the
remote control.
The unit stopped and TIMER indicator blinks.
FOR SEASONAL INSPECTION AFTER EXTENDED
FOR SEASONAL INSPECTION AFTER EXTENDED
NON-USE
NON-USE
• Checking of remote control batteries (wireless remote
control).
• No obstruction at air inlet and air outlet vents.
• Use Auto OFF/ON button to select Cooling/Heating
operation, after 15 minutes of operation, it is normal to
have the following temperature difference between air inlet
and air outlet vents:
Cooling: ≥ 8°C
FOR EXTENDED NON-USE
FOR EXTENDED NON-USE
• Activate Heat Mode for 2~3 hours to remove moisture left
in the internal parts thoroughly to prevent mould growth.
• Turn off the power supply.
• Remove the remote control batteries (wireless remote
control).
Check
Check
• Set the temperature correctly.
• Close all doors and windows.
• Clean or replace the fi lters.
• Clear any obstruction at the air inlet and air outlet vents.
• The unit is forced to operate at cooling mode only in a non-living room,
such as a computer room.
• Check if the unit has been installed at an incline or the intake grille is not
closed properly.
• Insert the batteries correctly.
• Replace weak batteries.
• Check if the circuit breaker is tripped.
• Check if timers have been set.
• Make sure the receiver not obstructed.
• Make sure the address is set correctly.
• Make sure the remote control signal transmission is within the range.
• Certain fl uorescent lights may interfere with signal transmitter. Please
consult your nearest dealer.
• Turn OFF the power supply to reset the unit (TIMER indicator stop blinking).
• Turn ON the power supply and restart the unit.
• If TIMER indicator blinks again, please consult your nearest dealer.
Heating: ≥ 14°C
NON SERVICEABLE CRITERIAS
NON SERVICEABLE CRITERIAS
TURN OFF POWER SUPPLY then CALL Authorized
Distributor under the following conditions:
• Abnormal noise during operation.
• Water/foreign particles have entered the remote control.
• Water leaks from Indoor unit.
• Circuit breaker switches off frequently.
• Power cord becomes unnaturally warm.
• Switches or buttons are not functioning properly.
13
Tabla de contenido
loading

Tabla de contenido