Product Description; Scope Of Delivery; Special Accessories; Clamping Devices - Bosch 0 986 610 825 Descripción Del Producto

Ui-p - reparación“ en el capítulo
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 31
3.

Product description

This section provides an overview of the most im-
portant devices and components of repair kit
0 986 610 825. The tool kit expands the existing repair
concept for UI-P to include:
R
Repair in the area of the solenoid valve
R
Measurement and adjustment of the remaining air
gap and the valve spring force
3.1

Scope of delivery

Designation
Clamping device; UI-P 1.x
Clamping device; UI-P 2
Measuring device;
Remaining air gap UI-P 1.x / UI-P 2
Hold-down; UI-P 1.x
Hold-down; UI-P 2
Parts set; spring assembly UI-P 1.x / UI-P 2
Leak tester; leak checking UI-P 1.x
Leak tester; leak checking UI-P 2
Hose assembly; leak checking
Mounting unit; vacuum generation
Adapter; vacuum connection UI-P 2
Adapter; vacuum connection UI-P 1.x
Conversion kit;
mounting device 0 986 613 400
Measuring device; UI-P 1.x / UI-P 2
Anvil; UI-P 1.x / UI-P 2
Dial gauge
Measuring element
Case; tool
Case; shims
Cans with screw-on cover (packaging unit
approx. 130 pcs); shims
Graduated disc
i
The order numbers in the 'Scope of delivery' chapter
are only for information.
3.2

Special accessories

Designation
Mounting plate
Force transducer
i
The item numbers in the "Special accessories" sec-
tion are for information purposes only.
i
The tools listed in the "Special accessories" section
are already used for repair of unit injectors.
Robert Bosch GmbH
Product description | 0 986 610 825 | 15
3.3
The conversion kit is used for the following purpose:
R
To increase safety in the workplace when handling
the mounting device 0 986 613 400.
!
Conversion of the mounting device 0 986 613 400 is
thus absolutely essential.
R
Add-on to the mounting device 0 986 613 400 for re-
pair in the area of the solenoid valve, measurement
and adjustment of the remaining air gap and valve
spring force (see also section 4 "Initial commission-
Part number
ing").
0 986 610 312
i
0 986 610 313
Detailed information on the conversion can be found
in the enclosed conversion instructions.
0 986 610 314
0 986 610 318
3.4
0 986 610 826
The mounting unit is used to generate vacuum
0 986 613 392
during assembly of the UI-P solenoid valve assembly.
0 986 610 829
The mounting unit is attached to mounting device
0 986 613 391
0 986 613 400 following installation of the conversion
0 986 610 795
kit 0 986 613 393 (see also section 4 "Initial commis-
0 986 610 897
1 687 023 753
sioning").
1 687 023 754
!
Ingress of particles from dirty compressed air can
0 986 613 393
result in malfunction. For this reason, only connect
0 986 613 394
the mounting unit to a compressed-air maintenance
0 986 610 898
unit with a water separator and filter having a pore
0 986 613 422
size of 0.01 μm (see also section 6 "Technical data").
1 683 521 101
0 986 613 930
3.5
0 986 613 940
The clamping devices are used to hold and secure UI-P
0 986 610 546
when used with mounting device 0 986 613 400:
R
0 986 613 425
Clamping devices 0 986 610 312 for UI-P 1.x
R
Clamping devices 0 986 610 313 for UI-P 2.x
!
The required clamping force is generated solely by
means of the "cross-shaped handle". Do not use any
mechanical aids for clamping. This could result in
damage to the clamping device or the UI-P.
Part number
i
0 986 613 429
Detailed information on operating and handling can
0 986 612 997
be found in the separate ESI[tronic] repair manual
UI-P.
!
In the event of damage or loss of any parts, the
respective clamping device must be replaced in its
entirety.
Conversion kit 0 986 613 393
Mounting unit 0 986 610 897

Clamping devices

1 689 989 245
en
|
2015-04-28

Capítulos

Tabla de contenido
loading

Tabla de contenido