Mini AC/DC Clamp/ English
• If the equipment is used in a manner not specified by the manufacturer, the protection
provided by the equipment may be impaired.
Input Limits
Function
Maximum Input
A
80A DC/AC
V DC, V AC
600V DC/AC
Frequency, Resistance, Diode, Continuity ,
250V DC/AC
Capacitance Test
2. Meter Description
1. Current clamp
2. Clamp trigger
1
3. Rotary Function swith
4. Data Hold button
5. Back Light button
6. LCD display
2
7. MODE select button
8. PEAK button
4
9. MAX/MIN button
6
10. Relative button
7
11. COM input jack
8
12. V CAP
11
12. TEMP Hz jack
2
AC DC
AUTO
H
o
o
C,
Hz%
MAX MIN
Pmax Pmin
3. Specifications
Function
3
DC Current
5
AC Current
9
(50/60Hz)
10
12
DC Voltage
02/12/2017 Version No. 001
02/12/2017 Version No. 001
AC (alternating current) and DC (direct currrent)
Minus sign
5000 count (0 to 4999)
measurement reading with 51 segments
Analog Bargraph
AutoRange mode
Relative mode
Diode test mode
Audible Continuity
Data Hold mode
F, μ, m, V, A, K, M, Ω, Units of measure list
Frequency/duty cycle test mode
MAX/MIN Hold mode
Pmax Pmin Hold mode
Range & Resolution
5000mA DC
80 A DC
DC Current ranges specified from 5% to 100% of range
5000mA AC
80A AC
AC Current ranges specified from 5% to 100% of range.
Below 10% of range, add 12 counts.
500 mVDC
5 VDC
50 VDC
500 VDC
600 VDC
Mini AC/DC Clamp/ English
Accuracy (% of reading)
± (2.8% + 20 digits)
± (3% + 8 digits)
± (3.0% +20 digits)
± (3.0% + 8 digits)
± (0.8% +6 digits)
± (1.5% + 2 digits)
± (2 % + 2 digits)
3