Step-by-step installation instructions.
Specifications/Dimensions
Rated Capacity*
Rated Efficiency**
Amount of High Capacity Resin (lbs/cu. ft)
Resin Tank Nominal Size (in., dia. x height)
Service Flow Rate (gpm)
Water Supply Maximum Hardness (gpg)
Water Supply Maximum Clear Water Iron (ppm)***
Water Pressure Limits (min.–max. psi)****
Pressure Drop at Rated Service Flow (psig)
Water Temperature Limits (min.–max. °F)
Maximum Flow Rate to Drain (gpm)
These systems conform to NSF/ANSI 44 for the specific capacity claims as verified and substantiated by test data.
*
Testing was performed using pellet grade sodium chloride as the regenerant salt.
**
Efficiency rating is valid only at the lowest stated salt dosage. These softeners were efficiency rated according to
NSF/ANSI 44.
*** Extent of iron removal may vary with conditions. The capacity to reduce clear water iron is substantiated by
WQA test data. State of Wisconsin requires additional treatment if water supply contains greater than 5 ppm
clear water iron. Use of Diamond Crystal
Cleaning Iron Out of the Water Softening System section.
**** Canada working pressure limits: 1.4–7.0 kg/cm
12
Sanitizing Procedures
To complete the installation, do the following
sanitizing procedures.
Care is taken at the factory to keep your
water softener clean and sanitary. Materials
used to make the softener will not infect or
contaminate your water supply and will not
cause bacteria to form or grow. However,
during shipping, storage, installing and
operating, bacteria could get into the
softener. For this reason, sanitizing as
follows is suggested when installing.
NOTE: Sanitizing is recommended by the
Water Quality Association for disinfecting.
1. Be sure to complete all installation steps,
including programming the control.
2. Pour about 3/4 oz. (1
1
common 5.25% unscented household bleach
(Clorox, Linco, Bo Peep, White Sail, Eagle,
etc.) into the brinewell. Refer to illustration
on page 5.
3. IMPORTANT: Press and hold for 3 seconds
the faceplate RECHARGE
an immediate recharge. RECHARGE begins to
flash in the display. The bleach will be drawn
through the water softener and out the drain.
This process takes approximately 2 hours.
®
Red•Out
®
or Super Iron Out
2
.
tablespoons) of
2
button to start
GXSF35E
GXSF40H
14,000 grains with 15,300 grains with
2.8 lbs. of salt
3.1 lbs. of salt
29,600 grains with 33,600 grains with
8.8 lbs. of salt
9.8 lbs. of salt
35,200 grains with 40,200 grains with
14.7 lbs. of salt
16.6 lbs. of salt
5,000 grains/lb.
5,100 grains/lb.
@ 2.8 lbs. of salt
@ 3.1 lbs. of salt
47.8/0.92
54.1/1.04
9 x 40
9 x 40
8.5
7.5
100
110
6
10
20–125
20–125
15
14
40–120
40–120
2.0
2.0
®
will improve iron removal. Refer to
4. If, after sanitization, water from the house
faucet tastes salty or has a slight color, this is
a preservative from the resin tank. Turn on
the cold soft water faucets and drain for a
few minutes or until clear.
NOTE: When the sanitizing recharge is over,
all remaining bleach is flushed from the
conditioner and your house COLD water supply
is fully soft immediately. However, your water
heater is filled with hard water and as hot water
is used, it will refill with soft water. When all the
hard water is replaced in the water heater, hot
only and mixed hot and cold water will be fully
soft. If you want totally soft water immediately,
after the above recharge, drain the water heater
until the water runs cold.
WARNING:
If you do drain the
water heater, use extreme care as the hot
water could cause burns. Turn the water
heater off prior to draining.
INLET–OUTLET
"
47
1
2
41
"
3
3
8
19"
"
16"
1
4