Troubleshooting - Olimpia splendid UNICO BOILER MASTER Instrucciones Para La Instalación, Uso Y Mantenimiento

Ocultar thumbs Ver también para UNICO BOILER MASTER:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

3
3.5.2

Troubleshooting

FAULTS
The unit does not turn on
The unit does not cool or
heat adequately
In the event the water heating up abnormally, a thermal safety switch conforming to CEI standards interrupts the
electrical circuit on both phases supplying the heating element with power; if this happens seek the intervention of
Service Assistance.
For the technical data listed below, consult the characteristic data plate applied to the product
- Power supply voltage
- Maximum power absorbed
- Maximum current absorbed
- Coolant gas
- Protection rating of the containers
- Max working pressure
Dimensions (W x H x D)
Weight (without packing)
Maximum operating temperature in cooling mode
Minimum operating temperature in cooling mode
Maximum operating temperatures in heating
Minimum operating temperatures in heating
COOLANT PIPELINE (not supplied)
- Maximum length of connecting pipeline 10 m
- Maximum height difference between internal and external unit 5 m
WATER TANK CAPACITY 50 LITRES
MAXIMUM WORKING PRESSURE ON WATER SIDE FOR UNICO BOILER MASTER PS 600 kPa (0.6 MPa)
54
POSSIBLE CAUSES
• No power supply
• The power switch is in "0" position
• The temperature set on the remote control is either
too high or too low (when using the
heating pump unit).
respective cleaning LED was switched on.
a door or a window was left open or equipment that
dissipates a large amount of heat was installed in the
same room);
• Both the internal units are running; the heating load is
greater than the power of each internal unit.
OPERATIONAL LIMITS
• Check that mains power is present (by turning on
• Check if the master switch is closed or if a fuse
• Check the temperature setting on the remote
• Switch off one of the two internal units.
UNICO BOILER MASTER
mm 902x516x229
kg 40
Internal ambient temp.
DB 35°C - WB 24°C
DB 18°C
DB 27°C
-
SUPPLY CABLES:
2
SOLUTIONS
a light for instance).
is burnt (in this case replace the fuse). If there is
a magnetothermal circuit breaker instead of the
Service Center at once and do not attempt to run
the unit.
A).
messages are displayed and that the unit's
you try to issue any command to it. In this case
replace the batteries.
control and correct it if need be.
UNICO BOILER WALL
mm 760x253x190
kg 8
Outside ambient temp.
DB 43°C - WB 32°C
DB -10°C
DB 24°C - WB 18°C
DB -15°C