Meaning Of The Leds - Comelit VEDOGSM4G Technical Manual

Ocultar thumbs Ver también para VEDOGSM4G:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

Sharing of
EGSM900, DCS1800, WCDMA B1/B8,
transmission
LTE FDD B1/B3/B7/B8/B20/B28
Class 4 (33 dBm ± 2 dB) for EGSM900
connections
Class 1 (30 dBm ± 2 dB) for DCS1800
Class E2 (27 dBm ± 3 dB) for EGSM900
8-PSK
Class E2 (26 dBm ± 3 dB) for DCS1800
8-PSK
Class 3 (24 dBm +1/-3 dB) for WCDMA
bands
Class 3 (23 dBm ± 2 dB) for LTE-FDD
bands
Voltage
10 ~ 15 V
operating range

MEANING OF THE LEDS

Name
Function
Off: Module not working
D1
Flashing quickly (64 ms On/ 800 ms
LED
Off): Module not connected to the
RED
network
Flashing slowly (64 ms On/ 2000 ms
Off): Module connected to the network
Module serial communication. Lights up
D3
briefly when the module communicates
LED
ORANGE
with the control panel.
Module serial communication. Lights up
D2
briefly when the module communicates
GREEN LED
with the control panel.
CONFIGURATION JUMPERS
Name
Function
LED
If disconnected, the LEDs go off
DBG
Reserved
RSDV
Reserved
CSL
Reserved
FITTING THE VEDOGSM4G MODULE
Make sure the board on which you intend to
fit the module is not connected to the power
supply.
IMPORTANT: any operation involving the assembly
or disassembly of expansion modules must be
performed with all input power (from power supply
unit or battery) OFF, in order to avoid permanently
damaging the expansion module you intend to add
or remove, as well as the control panel board.
„ Insert the plastic spacers in the relevant holes.
Then, taking care to plug the module connector
into the control panel connector designated MOD5
correctly, apply sufficient pressure to engage the
spacers in the GSM expansion card and plug the
connector in almost completely.
For the module to work, at least one of the two
antennas must be connected and fastened to
connector ANT1.
Connecting
the
second
performance in weak signal conditions.
The
antennas
perpendicular to one another!
„ Fasten the cable connector onto the gold-coloured
ANT1 connector on the VEDOGSM4G module.
„ If using the second antenna, proceed by fastening
the cable to the gold-coloured connector ANT2 on
the VEDOGSM4G module.
It is important that each antenna is connected
correctly and tightened fully.
Antenna presence can only be detected using
the antennas supplied. In all other cases antenna
presence detection must be excluded from the GSM
dialler options.
BOXMETAL HOUSING
Antenna positioning
OK !
Fig. 3
Fig. 1
antenna
improves
must
be
positioned
Fig. 2
9
Tabla de contenido
loading