Product Information; Installation Requirements - Wolf Steamer Module Guia De Instalacion

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 4
ST EAME R M O D U L E
Contents
Steamer Module
2
Specifications
2
Installation
3
Troubleshooting
3
Features and specifications are subject to change at any
time without notice.
Important Note
To ensure this product is installed and operated as safely
and efficiently as possible, take note of the following types
of highlighted information throughout this guide:
IMPORTANT NOTE
highlights information that is especially
important.
CAUTION
indicates a situation where minor injury or product
damage may occur if instructions are not followed.
states a hazard that may cause serious injury or
WARNING
death if precautions are not followed.
IMPORTANT NOTE:
Save these instructions for the local
electrical inspector.
|
2
English

Product Information

Important product information including the model and
serial number are listed on the product rating plate. The
rating plate is located on the bottom of the module. Refer
to the illustration below.
If service is necessary, contact Wolf factory certified service
with the model and serial number.
RATING
PLATE
Rating plate location.
S P E CIF IC ATIO N S

Installation Requirements

A minimum 51 mm is required from the bottom of the
steamer module to combustible materials. Refer to the
illustration on the following page for additional minimum
clearances.
The use of downdraft ventilation is not compatible with the
steamer module.
WARNING
Failure to locate the module without proper clearances
will result in a fire hazard.
DRA IN O UT L E T
Installation requires a method for draining water. Options
include connecting to an existing drain, or placing a heat-
resistant receptacle under the drain outlet. Refer to the
illustration on the following page for location of the drain
outlet.
Electrical
Installation must comply with all applicable electrical codes
and be grounded (earthed).
Locate the electrical supply as shown in the illustration on
the following page. A separate circuit, servicing only this
appliance is required.
Performance may be compromised if the electrical supply is
less than 220 volts.
When multiple cooktops or modules are installed side by
side, each unit must have its own separate recommended
electrical circuit.
EL EC T R I C AL R EQ U I RE MEN T S
Electrical Supply
220-240 VAC, 50/60 Hz
Maximum Connected Load
Open the terminal box to expose the screws with corre-
sponding numbers. Run the cord through the strain relief
hole and into the terminal box.
After tightening the screws, tighten down the cord strain
relief and close the cover to the terminal box without
pinching any of the wires.
IMPORTANT NOTE:
Connection of this appliance should be
through a fused connection unit or a suitable isolator, which
complies with national and local safety regulations. The
on/off switch should be easily accessible after the appli-
ance has been installed. If the switch is not accessible after
installation (depending on country) an additional means of
disconnection must be provided for all poles of the power
supply. When switched off there must be an all pole contact
gap of 3 mm in the isolator switch. This 3 mm contact dis-
connect gap must apply to any isolator switch, fuses and/or
relays according to EN60335.
RATING
PLATE
Rating plate location.
2.7 kW
Tabla de contenido
loading

Tabla de contenido