Auxiliary Displays
The Navigator Pro system can be easily setup with multiple displays controlling one valve . As long as the display is on
the same CAN network as the valve it is controlling, the valve can be assigned to that display . A single valve can be eas-
ily assigned to as many as 10 displays .
9-7/8"
5.1 ELECTRICAL INSTALLATION
Voltage Requirements:
The system has been designed to work on 12VDC or 24VDC systems . It will operate properly if the voltage is between
10VDC and 32VDC AT THE MOTOR . System voltage is not an adequate measurement to determine if the voltage is ap-
2-23/32"
propriate at the motor . To avoid excessive voltage drop and undesired operation, the wire gauge should be 12 AWG or
larger and the distance from power source to the motor should be no more than 30ft.
2-23/32"