13. Troubleshooting
Fault
Possible cause
The compressor does
•
No supply voltage.
not start.
•
Insufficient supply voltage.
•
Outside temperature is too low.
•
Motor is overheated.
The compressor starts
•
The non-return valve (19) leaks.
but there is no pressure.
•
The seals are damaged.
•
The drain plug for condensation water (10)
leaks.
The compressor starts,
•
The hose connections have a leak.
pressure is shown on
the pressure gauge, but
•
A quick-lock coupling has a leak.
the tools do not start.
•
Insufficient pressure set on the pressure
regulator (5).
Service information
Please note that the following parts of this product are subject to normal or natural wear and that the following parts are therefore also required
for use as consumables.
Wear parts*: intake filter
* Not necessarily included in the scope of delivery!
Remedy
•
Check the supply voltage, the power plug and the
socket-outlet.
•
Make sure that the extension cable is not too long. Use
an extension cable with large enough wires.
•
Never operate with an outside temperature of below
+5 °C.
•
Allow the motor to cool down. If necessary, remedy the
cause of the overheating.
•
Contact your local service centre. Every attempt to
carry out a repair, can be dangerous if it is not done by
skilled personnel.
•
Check the seals and have any damaged seals re-
placed by a service center.
•
Tighten the screw by hand..
Check the seal on the screw and replace if necessary.
•
Check the compressed air hose and tools and replace
if necessary.
•
Contact your local service centre. Every attempt to
carry out a repair, can be dangerous if it is not done by
skilled personnel.
•
Increase the set pressure with the pressure regulator.
GB/MT
39