Oase PondoVac 5 Instrucciones De Uso página 6

Ocultar thumbs Ver también para PondoVac 5:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

- English -
Opening/closing the tank
Attention! Dangerous electrical voltage.
Possible consequences: Death or severe injury.
Protective measures: Prior to commencing work, disconnect the unit from the mains.
1. Release the locking clips.
○ To do this, grip the clips from underneath and pull
upwards.
2. Lift off the vacuum head and the adapter ring.
○ The vacuum head and adapter ring can be removed
separately.
○ The plug connector for the discharge pump does not
need to be disconnected.
● Assemble the parts in the reverse order and fasten with
the locking clips.
○ Ensure that the parts are precisely aligned in relation
to each other.
○ Ensure that the seal on the adapter ring is correctly
seated so that it is not damaged during assembly.
Assembling the vacuum cleaner
Fitting the wheels
1. Insert the wheel into the wheel bush.
2. Firmly push the wheel until it locks into place.
Fitting the outlet
Prerequisite: The tank is open.
1. Check the correct seating of the adapter with non
return valve.
○ Ensure that the adapter is locked into place in the
tank wall.
2. Screw the Storz coupling type C onto the outlet and
hand-tighten.