BLOWER FEATURE
Your vacuum can be used as a powerful blower. To use the blower feature, clear the hose of any debris or
obstructions.
Unscrew blower port cover located on the back of tank cover. The port cover is equipped with a retaining
strap to prevent loss of the cover. NOTE: For maximum performance when vacuuming, remove the blower
port cover.
Insert machine hose end into blower port located on the back of the tank cover.
Twist the hose end slightly to tighten the connection. Caution should be used when using as a blower due to
the powerful force of air when using certain attachments.
WARNING
–
ALWAYS WEAR EYE PROTECTION TO PREVENT ROCKS OR DEBRIS
FROM BEING BLOWN OR RICOCHETING INTO THE EYES OR FACE WHICH CAN RESULT IN
SERIOUS INJURY.
EMPTYING LIQUID WASTE FROM THE TANK
To empty liquid waste from the tank, turn the vacuum off and remove the plug from the wall outlet. Follow
the instructions that pertain to your vacuum.
WITHOUT TANK DRAIN
Remove the tank cover and deposit the liquid waste in a suitable drain. Use side carry handles for lifting vac
when draining tank into drains that are located above floor level. After tank is empty, return the tank cover to
its original position.
WITH TANK DRAIN
Remove the drain cap and deposit the liquid waste in a suitable drain. Use side carry handles for lifting vac
when draining tank into drains that are located above floor level. After the tank is empty, return the drain
cap to it's original position.
AUTOMATIC SUCTION SHUT OFF
The vacuum is equipped with an automatic suction shut-off that operates when picking up liquids. As the
level of the liquid rises in the tank, an internal float rises until it seats itself against a seal at the intake of the
motor, shutting off suction. When this happens, the motor will develop a higher than normal pitch noise and
the suction is drastically reduced. If this occurs, turn unit off immediately. Failure to turn unit off after float
rises and shuts off suction will result in extensive damage to the motor. To continue use, empty the liquid
waste from the tank as outlined in the previous section.
NOTE : IF ACCIDENTALLY TIPPED OVER, THE VACUUM COULD LOSE SUCTION, IF THIS OCCURS, TURN UNIT
OFF AND PLACE VAC IN UPRIGHT POSITION. THIS WILL ALLOW THE FLOAT TO RETURN TO ITS NORMAL
POSITION AND YOU WILL BE ABLE TO CONTINUE OPERATION.
LUBRICATION
No lubrication is necessary as the motor is equipped with lifetime lubricated bearings.
STORAGE
1. Before storing your vacuum the tank should be emptied and cleaned.
2. The power cord can be wrapped around the cord wraps provided on back of the tank cover.