INSTALLATION
- If the drain is run to a tank or butt, avoid installing the
condensed water pipe with its free end submerged in water
(see Figure 9.2).
Fig. 9.2
Avoiding submerging the end.
- Do not allow the drain line to be kinked or flattened which
could reduce the flow of water from the indoor unit (see
Figure 9.3).
Fig. 9.3
Avoid kinking the pipe.
- For drain pipes run to ground level outside, install the
condensed water pipe in such a way that the distance of its
EN
free end from the floor is at least 5 cm (see Figure 9.4).
Fig. 9.4
Minimum distance from the floor.
Legend
H
Minimum distance from the floor: 5 cm
- Install the condensed water pipe in such a way that its free
end is kept away from unpleasant odours, such as from open
- 12 -
drains, to ensure that they are not drawn back into the unit
(see Figure 9.5).
Fig. 9.5
Avoids unpleasant odours.
SDH17-MNW-I_EN - 03/13 - Saunier Duval