4.4- Input wiring:
The control unit is supplied with jumpered normally closed inputs (stop, photo and stpa) remove the jumper from the input you are going to use.
Terminal number
19
20-23
21
22
24
25
26
4.5- Connecting control buttons and key switch,
in parallel are operated (the APCH input controls opening or closing the gate completely, the APED input controls opening or closing motor output 1:
Button controlling APCH
Button controlling APED
4.6- Connection of timer or detector with magnetic induction with normally open contact (the open LED comes
on when the timer or magnetic induction detector are operated) the OPEN input commands opening of the 2 gate
leaves, until the contact is closed, the gate opens and remains in the open position, the APCH, APED commands
and saved remote controls are not active until the contact is reset from closed to open, after the automatic closing
time set with the PAUSE trimmer, the gate closes, this input is used to open and hold open the gate at the times
of greatest influx:
18
Opening-only button input, dedicated for timer or detector for magnetic induction coils
Control inputs common (permanent GND)
Sequential control input, for controlling 2 gear motors
Sequential control input, for controlling gear motor 1
Input for stopping the gate
Photocell input, active during gate closing
Input for edges or internal photocell, active during gate closing and opening
normally open contacts the AP/CH or aped LEDs come on when the selector or the buttons connected
Fig. 6
Description
COM
N.O.
Input type
normally open
normally open
normally open
Normally closed
Normally closed
Normally closed
COM
N.C. N.O.
N.C.
12
1
11
2
10
3
9
8
4
7
5
6
TIMER
-
Fig. 7
EN