Trimmer For Adjustments; Dip Switch Functions - Vimar ELVOX RS11 Manual De Instalación Y Funcionamiento

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 44
Programming and deleting the remote control.
The first saved remote control sets the type of remote controls that can be used (rolling code or hard code)
programming the button of the remote control associated with the AP/CH input:
- Press and hold down the P2 button until the DL8 LED starts flashing slowly, release button P2
- Press the button of the remote control to save as the opening and closing command for the 2 gate leaves, within 10 seconds
- The DL8 LED comes on with a steady light for 2 seconds and then goes out, the remote control is saved, to save other remote controls, repeat the above
procedure.
Programming the button of the remote control associated with the APED input or 2CAN output, see dipswitch number 3:
- Press and hold down the P2 button until the DL8 LED starts flashing quickly, for approximately 4 seconds, release button P2
- Press the button of the remote control to save as the pedestrian gate opening command or 2CAN output activation, within 10 seconds
- The DL8 LED comes on with a steady light for 2 seconds and then goes out, the remote control is saved, to save other remote controls, repeat the above
procedure.
Deleting all the saved remote controls:
Press and hold down the button P2, until the DL8 LED first starts blinking and then increases the speed of flashing, when the DL8 LED turns off release the
button P2.
At the end of this procedure all the remote controls in memory are deleted, the first remote control learned sets the type of remote controls that can be saved
in the control panel.
The maximum capacity is 128 remote controls, on reaching the maximum capacity, when entering remote control programming (the DL8 LED flashes) on
pressing the button of the new transmitter to be saved, the DL8 LED makes three quick flashes.

8- Trimmer for adjustments:

Trimmer
TR1- Pause
TR2-Force M1
TR3-Force M2
TR4-Slowdown speed

9- Dip switch functions:

After setting the dip switches it is necessary to jumper the jr1 reset contacts for a few seconds or switch power off and back on again for the change to be
updated by the control panel:
Dip switch number
Status of dip switch
DIP 1-1
DIP 1-1
DIP 1-2
DIP 1-2
DIP 1-3
DIP 1-3
DIP 1-4
DIP 1-4
DIP 1-5
DIP 1-5
DIP 1-6
DIP 1-6
DIP 1-7
DIP 1-7
DIP 1-8
DIP 1-8
DIP 2-1
DIP 2-1
DIP 2-2
DIP 2-2
EN
Function
Automatic closing time
Motor force M1
Motor force M2
Slowdown speed
OFF
ON
OFF
ON
Pre-flashing on, before the gate moves the flashing light comes on for 3 seconds
OFF
The 2CAN output is associated with the second channel of the remote control
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
Photo-test function on (photocell checking with each command) see paragraph 4.8
OFF
ON
OFF
ON
From 1 to 120 seconds maximum clockwise
From 30 to 100%, maximum, clockwise (with trimmer on
Description
Electrical lock connection and disconnection not enabled
Electrical lock connection and disconnection enabled
Pre-flashing off
The 2CAN output is used to feed the photocell transmitters
The STPA input used for the internal photocell connection
The STPA input used for the resistive sensitive edge connection
See table for control input operating logic
Photo-test function off
Not used
Not used
Pick-up on starting ON
Pick-up on starting OFF
Range
From 20 to 100%, maximum, clockwise
From 20 to 100%, maximum, clockwise
maximum slowdown is disabled)
23
Tabla de contenido
loading

Este manual también es adecuado para:

Elvox rs11.120

Tabla de contenido