POSSIBLE BREAKDOWNS, CAUSES AND SOLUTIONS
PROBLEMS
THE PUMP DOES NOT PRIME
THE PUMP GIVES LOW FLOW
THE MOTOR STOPS
7. SPECIFICATIONS

7.1. PRODUCT AND ACCESSORY DESCRIPTION

The pump body is made from state of the art thermoplastics. The pumps are of a self-suction until a
peak altitude of 2 meters, and they are provided with three-phase motors of 3, 4 and 5.5 HP.
A pre-filter has been incorporated into the pump body to prevent foreign bodies from entering and
damaging the pump's hydraulic parts.
The motors supplied with the pump unit have been protected by IP-55 and are prepared to withstand
hot atmospheres and high humidity levels.
7.2. ELEMENTS SUPPLIED
Self-suction pump for water circulation in swimming pools.
Pre-filter incorporated in the pump body.
Pre-filter basket.
Joints and linking pipe unions for impulsion and suction tubing connections.
Pump installation and maintenance manual.
The motor pump unit's functional characteristics are given in the different characteristic curves.
CAUSES
Air entry in suction tube
Bad filter cover sealing
Motor turning direction incorrect.(III)
Blocked pre-filter
Air entry in suction tube
Motor turning direction incorrect.(III)
Load loss in suction
Wrong voltage
Increase in terminal box
temperature because of voltage
arch effect
Heat protector blows
Terminal boxes badly connected
35
SOLUTIONS
Check pipe fittings and suction
tube joints
Clean the pre-filter cover and
check the condition of the joint
Invert two phases of the feeding
line
Clean the pre-filter
Check pipe fittings and suction
tube joints
Invert two phases of the feeding
line
Prevent as much as possible,
elements that produce load loss
Check that the network voltage
corresponds to that on the motor
specification board
Check terminal box connections
Correctly connect cables with
terminal box terminals
Fasten the cable to the terminal
correctly
Modify size of connection cable to
terminal box terminals