Safety Indications - IML BIG DISCOVERY DY350T Manual De Instalación Y Mantenimiento

Ocultar thumbs Ver también para BIG DISCOVERY DY350T:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

POSITIONING
The pumps are of a self-suction type even though assembly below the swimming pool or
tank water level is advised to improve performance.
Should it be necessary to install the pump above the water level, the difference in height
should not be more than 2 metres. Ensure that the suction tube is as short as possible
since a long tube increases suction time and facility load loss.
It should be ensured that the pump is free from possible flooding and it is given dry
ventilation.

SAFETY INDICATIONS

ALL THE ELECTRICAL INSTALLATIONS MUST COMPLY WITH STANDARD: EN 60335-2-41
"All 230 V single-phase or 400 V electrical units must be installed at a minimum distance of 3,5
meters from the edge of the pool. In the case of a modification on the filtration system, the
manufacturer must be informed".
ELECTRICAL UNIT
The electrical unit should have a multiple separation system with contact opening of at
least 3 mm.
Connection to the mains can only be done using a rigid cable. In the event that a flexible
cable is used this should have terminals to connect it to the pump motor terminals.
In the three-phase motor a motor guard with heat-magnetic protection needs to be used.
A protection differential of 0.03 A is needed for any pump in order to protect from
electrical escapes (shown in diagrams).
Three-phase motors should be protected from overload by a safety switch for the motor.
The heat relay regulation data for the single-phase motor are merely illustrative since the
motor comes with an incorporated protector.
Fig.3
31