Mixer Valve
Spout
Shank
Spout Plug
2. Install the Supplies
CAUTION: Risk of property damage. When installing the
handle on either the right or the left side of the spout,
connect the supplies to the mixer valve with the cold supply
line plumbed on the left and the hot supply line plumbed on
the right. For left side handle installation, disregard the cold
label on the mixer valve.
IMPORTANT! The illustration shows a right side handle
installation. The supply can also be installed with the handle on the
left side.
Install 1/2" supply lines to the mixer valve with the cold supply
on the left and the hot supply on the right.
Temporarily remove and retain the plaster guard/tool and spout
plug.
Position a bucket in front of the spout shank, then turn on the
water supplies to the mixer valve.
Slowly open the valve stem. Allow hot and cold water to flow
from the water supplies for approximately 1 minute to remove
any debris.
Close the valve stem. Check all connections for leaks.
Reattach the plaster guard/tool and spout plug.
1095311-2-J
Hot Supply
Valve Stem
Cold Supply
Plaster
Guard/Tool
4
Kohler Co.