Blast Chilling And Conservation; Hard Blast Chilling And Conservation; Deep Freezing And Conservation - Diamond Diverso WR-3G0P-EC Manual Del Usaurio

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

6.3A BLAST CHILLING AND CONSERVATION
The temperature-controlled blast chilling and conservation cycle is divided into the following two phases:
• Blast chilling
• Conservation
On conclusion of a phase, the device passes automatically to the next.
Operate as indicated to start the cycle:
• Press and release the blast chilling key: the blast chilling LED and the core probe LED will flash.
• Pressing again the blast chilling key the system passes from the temperature control to the time control (in this
case, the blast chilling LED and the time LED will flash).
• Selecting the temperature control, the display will show the temperature that the probe will detect at the end of
blast chilling.
• By selecting the time control, the display will show the duration of the cycle.
• After selecting the type of blast chilling (temperature or time control) it is possible to modify the end cycle value
by pressing (within 15 seconds) the key increase or the key decrease until reaching the chosen value.
• At this point, to start the cycle press and release the start/stop key.
• If the temperature control has been selected, the system starts a test to verify the correct insertion of the probe.
If the test is successfully completed the cooling cycle will start; otherwise a time-controlled cooling cycle will be
started (in this case, the probe led turns off and the time led lights up).
• To stop the cooling cycle, keep pressed the start/stop key.
• During temperature-controlled chilling, the cell temperature can be displayed by pressing the blast chilling key.
After 15 seconds, the display returns to displaying the temperature detected by the probe.
• If the temperature detected by the probe reaches the blast chilling end value within the maximum expected du-
ration, the cycle will be considered correct and the blast chiller will automatically go to the conservation phase.
• When switching from blast chilling to conservation phase, the buzzer is activated for a set time.
• During storage, the display shows the temperature detected by the probe and the LED conservation lights up
in the lower part of the display.
• If the temperature detected by the probe does not reach the blast chilling end value within the maximum expect-
ed duration, blast chilling will not be completed correctly but will continue.
• The probe LED will flash and the buzzer will be activated.
6.3B HARD BLAST CHILLING AND CONSERVATION
The temperature-controlled hard blast chilling and conservation cycle is divided into the following three phases:
• blast chilling hard phase
• blast chilling
• conservation
On conclusion of a phase, the device passes automatically to the next.
Operate as indicated to start the cycle:
• Press and release the blast chilling key: the blast chilling LED and the core probe LED will flash.
• Press and release the hard/soft key (the hard LED will flash).
• At this point, to start the cycle press and release the start/stop key.
6.3C DEEP FREEZING AND CONSERVATION
The temperature-controlled deep freezing and conservation cycle is divided into the following two phases:
• Deep freezing
• Conservation
On conclusion of a phase, the device passes automatically to the next.