3. Location
IMPORTANT
1. This icemaker is not intended for outdoor
use. Normal operating ambient temperature
should be within +7°C to +40°C. Normal
operating water temperature should be within
+7°C to +35°C. Operation of the icemaker,
for extended periods, outside of these normal
temperature ranges may affect production
capacity.
2. The icemaker should not be located next to
ovens, grills or other high heat producing
equipment.
3. The location should provide a firm and level
foundation for the equipment.
4. Allow 15 cm. clearance at rear, sides and
top for proper air circulation and ease of
maintenance and/or service should they be
required.
5. This appliance is not suitable for installation
in an area where a water jet could be used
and where dripping is not allowed.
6. Do not place anything in front of the louver.
7. This icemaker will not work at subfreezing
temperatures. To prevent damage to the
water supply line, drain the icemaker when
air temperature is below zero.
4. Installation
• The installation must be carried out by qualified
personnel, in accordance with current regulations,
according to the manufacturer's instruction.
• Incorrect installation can cause harm to people,
animals, the icemaker, or the installation location, for
which the manufacturer cannot be held responsible.
1) Unpack the storage bin, and attach the four
adjustable legs provided (bin accessory) to the
bottom of the storage bin.
2) Position the storage bin in the selected permanent
position.
3) Place the icemaker onto the top of the storage
bin taking care not to damage the bin top sealing
gasket.
4) From the accessory pack, locate the two universal
braces and bolts to secure the icemaker to the bin.
(See Fig. 2).
5) Level the icemaker/storage bin in both the left-to-
right and front-to-rear directions by turning the bin
leg adjusters with a wrench.
6) Make sure the bin control thumbscrews are tight.
7) Replace the panels in their correct positions.
5. Electrical Connection
WARNING
THIS APPLIANCE MUST BE EARTHED
This icemaker requires an earth that meets the
national and local electrical code requirements.
To prevent possible severe electrical shock to
individuals or extensive damage to equipment,
install a proper earth wire to the icemaker. Turn
off the power supply before any maintenance,
repairs or cleaning is undertaken.
• This icemaker must have a separate power supply
or receptacle of proper capacity. See the nameplate.
It is recommended that this icemaker be the only
electrical device on its power supply circuit.
• Usually an electrical permit and services of a licensed
electrician are required.
• If a power cord and/or a plug should need to be fitted/
replaced, it should only be done by a qualified service
engineer.
• Factory fitted power cords are coloured in accordance
with the following code:
Green & Yellow = Earth
Blue = Neutral
Brown = Live
3
ENGLISH
Fig. 2