TROUBLE
1. Fan will not start.
2. Fan sounds noisy.
3. Fan wobbles
excessively.

9. Troubleshooting

PROBABLE CAUSE
1. Fuse or circuit breaker blown.
2. Loose power line connections to the fan,
or loose switch wire connections in the
switch housing.
1. Blades not attached to fan.
2. Loose screws in motor housing.
3. Screws securing fan blade flanges to
motor hub are loose.
1. Setscrews in motor coupling are loose.
2. Setscrew in hanger ball / downrod
assembly is loose.
3. Hanger bracket and / or ceiling outlet
box is not securely fastened.
4. Fan blades out of balance.
SUGGESTED REMEDY
1. Check main and branch circuit fuses or circuit
breakers.
2. Check line wire connections to fan and switch
WARNING: Make sure main power is turned
wire connections in the switch housing.
OFF.
!
1. Attach blades to fan before operating.
2. Check to make sure all screws in motor housing
are snug (not over-tight).
3. Check to make sure the screws which attach
the fan flanges to the motor hub are tight.
WARNING: Make sure main power is turned
OFF.
!
1. Tighten both setscrews securely in the motor
coupling.
2. Tighten the setscrew in the hanger ball / downrod
assembly.
3. Tighten the hanger bracket screws to the outlet
box, and / or secure outlet box.
4. Interchanging an adjacent (side-by-side) blade
pair can redistribute the weight and result in
smoother operation.