Enter the setting
ENTER
Press during 30 seconds to
enter the setting.
SEt
- P -
SEt
APP
SEt
LEA
SEt
b .P
SEt
- b -
SEt
- d -
SEt
- U -
Guard control
setting.
On
- P -
ON / OFF to turn off or turn on the
guard control.
Standarization display
setting.
5
APP
Set the pace to 1g/5g or 0.1oz0.25oz,
the result of the measurement will be
shown by the multiple set.
The least value setting of
unbalancing.
5
LEA
This is set between 1g-40g o
0.1o1.5oz, smaller than what will be
shown "0"
Buzzer switch setting
On
b .P
ON / OFF to start or stop the buzzer's
sound announcement
Width input unit setting
0.0
- b -
"0" means inch as unite
"0" means mm as unite
Diameter input unit setting
SEt
ENTER
SEt
ENTER
A a
A a
d
d
S
S
SEt
ENTER
SEt
ENTER
SEt
ENTER
SEt
ENTER
SEt
ENTER
00
"0" means inch as unite
- d -
t
"0" means mm as unite
Unbalanced weight
unit setting
Gr
- U -
"Gr"means gram as unit
"Oz"means ounce as unit
Save and exit
CALIBRATION PROGRAMS
It is used to initialize the new machine and re-
move the old equipments' measurement errors
caused by total loss from use , parts ageing and
replacing, or strong impact.
Calibration procedures include unbalance cali-
bration and automatic gauge calibration.
Apagado
Apagado
Press
or
Stop
Stop
tion program.
UNBALANCE CALIBRATION
Choose a wheel with small unbalanced value
and install it on the balancer. Input the wheel
parameters then calibrate.
Press button " FINE" 3
seconds show
Add,0,0,then lose hand.
Press START the first time
,rotating machine.
At 12 o'clock position of
outside wheel strike 100g
weights ( outside 5 indi-
cator lights all brighten )
Press again the second
time ,rotating machine
At 12 o'clock position of
inside wheel strike 100g
weights (inside 5 indicator lights all brighten )
The third time ,rotating machine ,calibration
complete automatically preserve the result
after finishing measure automatically return
back original state after finishing measure.
Exit
Apagado
Apagado
Stop
Stop
key to exit calibra-
29