OPT FUNCTION
OPT function is used to determine the best ma-
ting of tire and rim. When doing dynamic and
static modes, if the static mode value is greater
than OPT value (implied 30g), the system
will start optimization.
OPT
When optimization is possible,
press key to operate
When optimization is not possible, display
"OFFOPT" and exit OPT operation.
OPT
Press OPT key
to start.
Step 1
Rotate the gas nozzle to 12 o'clock. Press
ENTER key to memorize the point. Mark with a
chalk a reference mark on the tire.
Step 2
Remove the wheel from the balancer using a
tire changer. Align the nozzle and the mark by
rotating the tire on the rim by 180 degrees.
Step 3
Replace the wheel on the balancer and rota-
te the gas nozzle to 12 o'clock again. Press
"ENTER" key to memorize.
Step 4
Press START key to start OPT measurement.
After measurement, mark with chalk again
on the tire the marked point indicated on
the screen. Using the changer to assemble
until the new mark and the gas nozzle coin-
cide. Now the value displayed is the rest value
after optimization. On this point add 10g cou-
nterweight.
Press ENTER to end optimization.
28
MOT
MOTOCYCLE MODE
Motorcycle mode is the same as standard dy-
namic mode except that it needs special mo-
torcycle fixtures and extending arms.
SYSTEM SETTINGS
System setting is used to set options , such as
the application control state , the commonly
used units of this equipment and so on.
Ways to enter: In any mode, press SET to enter.