Problem
Possible Cause
Corrective Action
Low heat,
LP gas
Sudden drop in gas
flow or low flame
Cooking light will not
turn on.
The propane regulator
assembly incorporates an excess
flow device designed to supply the
grill with sufficient gas flow. Rapid
changes in pressure can trigger the
excess flow device, providing a low
flame
and low temperature.
1. Out of gas.
2. Excess flow valve tripped.
3. Vapor lock at coupling nut/LP
cylinder connection.
1. No power supply.
2. Defective halogen bulb.
3. Internal wiring issue.
Please follow these instructions:
1. Make sure all burners are "OFF".
2. Open the tank valve and wait 5
minutes.
3. Light the burner one at a time
following the lighting instructions
listed on the door liner
1. Check for gas in LP cylinder.
2. Turn off knobs, wait 30 seconds and light
grill. If flames are still low, turn off knobs
and LP cylinder valve. Disconnect
regulator. Reconnect regulator and leak
test. Turn on LP cylinder valve, wait 30
seconds and then light grill.
3. Turn off knobs and LP cylinder valve.
Disconnect coupling nut from cylinder.
Reconnect and retry.
1. Check power supply and make sure
transformer is properly plugged in.
2. Replace the bulb.
3. Check the wiring connections under the
fire box. All wire connections must be
tight. If any wires are damaged they
should be replaced.