Preliminary Procedures - Vimar ELVOX 7548 Instrucciones Instalador

Videoportero tab con microteléfono 4,3”
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 28
TAB: 7548

Preliminary procedures

After having installed the device, it must be programmed, giving it
an identification number (ID), which is unique for each appliance.
The BASIC programming is described below, which can be done
with the device's keyboard.
All programming operations must be performed with the indoor
unit on standby.
For ADVANCED programming, use the SaveProg software for PC.
Programming ID identification code
The identification code is programmed with a configured MASTER
entrance panel.
An indoor unit with no ID code programming beeps three times when
the
button is pressed
1) Lift the handset and place to the ear.
2) Press the
and
buttons simultaneously and keep them
pressed until the
button starts blinking.
3) Release the buttons.
4) Press the
button within 5s of releasing the buttons and keep
it pressed until you hear a warning tone on the handset and the
communication is activated between the indoor unit and the ex-
ternal electronic unit. If more than 5s passes without the
button being pressed, steps 1, 2 and 3 must be repeated.
5) Release the
button.
6) Within 25s, pair the ID code from the external electronic unit, fol-
lowing the procedure described on the speech unit (pushing a
button, internal keyboard entry).
NOTE: If the installation already contains an indoor unit with the
same paired identification code, the entrance panel will emit a tone
and the process must be repeated from the start in order to assign
a different code.
Programming secondary ID
The secondary identification code is programmed when the same
call has to activate multiple indoor units at the same time (max 4
composed of 1 Master and 3 secondary ones). You need to define a
Master indoor unit which can be paired with up to 3 indoor units with
a secondary ID. At most 50 Master ID codes can be programmed
in this way.
1) Lift and place to the ear the handset of the indoor unit.
2) Press the
and
buttons simultaneously and keep them
pressed until the
button starts blinking.
3) Release the buttons.
4) Press the
and
buttons simultaneously within 5s of re-
leasing the buttons and keep them pressed until you hear a warn-
ing tone on the indoor unit and the communication is activated
between the indoor unit and the external electronic unit. If more
than 5s passes without the
steps 1, 2 and 3 must be repeated.
5) Release the
and
6) Within 25s, pair the ID code of the Master from the electronic unit,
following the procedure described on the speech unit (pushing a
button, internal keyboard entry).
Note: Use the SaveProg software to program chime activation of all
the monitors and switching on only the master monitor.
Note: To delete from a group, the programming deletion procedure
and
buttons being pressed,
buttons.
described in the "Default data restore procedure" section must be
performed.
Button programming
1) Raise and place to the ear the handset of the indoor unit to pro-
gram (caller).
2) Press the
and
buttons of the indoor unit to program (call-
er) and keep them pressed until the
3) Release the buttons.
4) Press and hold down the
5) Wait for the indoor unit to emit a continuous tone.
6) Release the button.
7) Press a button on the indoor unit to call (
8) An audible warning on the calling indoor unit confirms that the
procedure has correctly completed.
Programming the
electronic unit
1) Lift the handset and place to the ear.
2) Press the
and
pressed until the
button starts blinking.
3) Release the buttons.
4) Press and hold down the
5) Wait for the indoor unit to emit an audible warning.
6) Release the button.
7) Call the indoor unit from the entrance panel on which you want
direct self-starting (pressing a button, internal keyboard entry or
selecting the name from the contacts list).
8) At the end of the procedure described above, the indoor unit emits
a signal to confirm that the operation has been successful and it is
called by the entrance panel.
Procedure for restoring default programming for
the button
1) Lift the handset and place to the ear.
2) Press the
and
pressed until the
button starts blinking.
3) Release the buttons.
4) Press and hold down the
5) Release the button and press the button again, the indoor unit
emits a signal to confirm that the operation has been successful.
Note: to reprogramme buttons
software.
Programming procedure for the levels of contrast
and brightness of the LCD
1) Lift the handset and place to the ear.
2) Press the
and
pressed until the
button starts blinking.
3) Release the buttons.
4) Press one of the 4 buttons beneath the handset:
. Self-starting is performed on the first programmed speech
EN
for intercom calls
button starts blinking.
button.
/F1/F2/
self-start button for a specific
buttons simultaneously and keep them
button.
buttons simultaneously and keep them
button until the indoor unit beeps.
and
use the SaveProg
buttons simultaneously and keep them
,
).
,
,
19
Tabla de contenido
loading

Tabla de contenido